Network requirements, Configuring router a – H3C Technologies H3C MSR 50 User Manual

Page 776

Advertising
background image

391

Configuring local SIP server to operate in alive mode

Network requirements

Router A and Router B carry out call services through the remote voice server VCX. Configure the local

SIP server on Router A to operate in alive mode, so that calls can be originated or received through

Router A when the VCX fails. When the VCX recovers, it will take over call services again.

Figure 777 Network diagram

Configuring Router A

# Configure the IP address of Ethernet 1/1 as 1.1.1.2, and the IP address of the sub interface as 2.1.1.2.

(Details not shown.)
# Configure the local SIP server to operate in alive mode.

1.

Select Voice Management > SIP Local Survival > Service Configuration from the navigation tree to

access the following page.

Figure 778 Configuring alive mode

2.

Select Enable for Server Running State.

3.

Enter 2.1.1.2 in IP Address Bound to the Server.

4.

Select Alive for Server Operation Mode.

Advertising