D382, Advanced display group (continued) – Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual

Page 105

Advertising
background image

Rockwell Automation Publication 520-UM001G-EN-E - September 2014

105

Programming and Parameters

Chapter 3

Advanced Display Group (continued)

d382 [Torque Current]

Displays the current value of the motor torque current measured by the drive.

Values

Default:

Read Only

Min/Max:

0.00/(Drive Rated Amps x 2)

Display:

0.01 A

d383 [PID1 Fdbk Displ]

d385 [PID2 Fdbk Displ]

PowerFlex 525 only.

Displays the active PID Feedback value.

Values

Default:

Read Only

Min/Max:

0.0/100.0%

Display:

0.1%

PF 525

d384 [PID1 Setpnt Disp]

d386 [PID2 Setpnt Disp]

PowerFlex 525 only.

Displays the active PID Setpoint value.

Values

Default:

Read Only

Min/Max:

0.0/100.0%

Display:

0.1%

PF 525

d387 [Position Status]

PowerFlex 525 only.

Displays the present operating condition of the drive. When in Positioning mode, Bit 1 indicates positive or negative position in relation to Home.

Values

Default:

Read Only

Min/Max:

0000/1111

Display:

0000

PF 525

1 = Condition True, 0 = Condition False

Dir Positive

Digit 1

At Position

Digit 2

At Home

Digit 3

Drive Homed

Digit 4

Not Used

d388 [Units Traveled H]

Related Parameter(s):

d387

Stop drive before changing this parameter.

32 bit parameter.

PowerFlex 525 only.

Displays the number of user-defined units traveled from the home position. See

d387

[Position Status] for direction of travel.

Values

Default:

Read Only

Min/Max:

0/64000

Display:

1

32

PF 525