Rockwell Automation Publication 520-UM001G-EN-E - September 2014

Chapter 3

Programming and Parameters

Advanced Display Group (continued)

d389 [Units Traveled L]

Related Parameter(s):

d387

Stop drive before changing this parameter.

PowerFlex 525 only.

Displays the number of user-defined units traveled from the home position. See

d387

[Position Status] for direction of travel.

Values

Default:

Read Only

Min/Max:

0.00/0.99

Display:

0.01

PF 525

d390 [Fiber Status]

Present status of the Fibers features.

Values

Default:

Read Only

Min/Max:

0000/1111

Display:

0000

1 = Condition True, 0 = Condition False

Sync Hold

Digit 1

Sync Ramp

Digit 2

Traverse On

Digit 3

Traverse Dec

Digit 4

Not Used

d391 [Stp Logic Status]

Related Parameter(s):

P047

,

L180

-

L187

32 bit parameter.

PowerFlex 525 only.

Displays the current step of the Step Logic profile as defined by parameters

L180

...

L187

[Step Logic x] when

P047

[Speed Reference1] is set to 13 “Step Logic” or 16 “Positioning”.

Values

Default:

Read Only

Min/Max:

0/8

Display:

1

32

PF 525

d392 [RdyBit Mode Act]

Related Parameter(s):

A574

PowerFlex 525 only.

(With FRN 3.xxx and later.)
Displays the value of

A574

[RdyBit Mode Cfg].

Values

Default:

Read Only

Min/Max:

0/1

Display:

1

PF 525