B025, Basic display group (continued) – Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual

Page 75

Advertising
background image

Rockwell Automation Publication 520-UM001G-EN-E - September 2014

75

Programming and Parameters

Chapter 3

Basic Display Group (continued)

b025 [Accum Cost Sav]

Related Parameter(s):

b024

,

P052

,

A555

Total approximate accumulated cost savings of the drive compared to using an across the line starter.
[Accum Cost Sav] = [Average kWh cost] x [Accum kWh Sav]

Values

Default:

Read Only

Min/Max:

0.0/6553.5

Display:

0.1

b026 [Accum CO2 Sav]

Related Parameter(s):

A555

Total approximate accumulated CO2 savings of the drive compared to using an across the line starter.

Values

Default:

Read Only

Min/Max:

0.0/6553.5 kg

Display:

0.1 kg

b027 [Drive Temp]

Present operating temperature of the drive heatsink (inside module).

Values

Default:

Read Only

Min/Max:

0/120

°C

Display:

1

°C

b028 [Control Temp]

Present operating temperature of the drive control.

Values

Default:

Read Only

Min/Max:

0/120

°C

Display:

1

°C

b029 [Control SW Ver]

Current drive firmware version.

Values

Default:

Read Only

Min/Max:

0.000/65.535

Display:

0.001

Advertising