A534, A531, A532 – Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual

Page 121: A533, Advanced program group (continued)

Advertising
background image

Rockwell Automation Publication 520-UM001G-EN-E - September 2014

121

Programming and Parameters

Chapter 3

Advanced Program Group (continued)

A531 [Start Boost]

Related Parameter(s):

P031

,

P032

,

P039

,

A530

Sets the boost voltage (% of

P031

[Motor NP Volts]) and redefines the V/Hz curve when

A530

[Boost Select] = 0 “Custom V/Hz” and

P039

[Torque Perf Mode] = 0 “V/Hz”.

Values

Default:

2.5%

Min/Max:

0.0/25.0%

Display:

0.1%

Frequency

Voltage

[Break Frequency]

[Motor NP Hertz]

[Maximum Freq]

[Start Boost]

[Motor NP Volts]

[Maximum Voltage]

[Break Voltage]

[Minimum Freq]

A532 [Break Voltage]

Related Parameter(s):

P031

,

P032

,

P039

,

A530

,

A533

Sets the voltage (in percent of [Base Frequency]) at the

A533

[Break Frequency] if

A530

[Boost Select] is set to 0 “Custom V/Hz”.

Values

Default:

25.0%

Min/Max:

0.0/100.0%

Display:

0.1%

A533 [Break Frequency]

Related Parameter(s):

P031

,

P032

,

P039

,

A530

,

A532

Sets the frequency where

A532

[Break Voltage] is applied if

A530

[Boost Select] is set to 0 “Custom V/Hz”.

Values

Default:

15.0 Hz

Min/Max:

0.0/500.0 Hz

Display:

0.1 Hz

A534 [Maximum Voltage]

Related Parameter(s):

b004

Sets the highest voltage the drive outputs.

Values

Default:

Drive Rated Volts

Min:

10V AC (on 230V AC Drives); 20V AC (on 460V AC Drives); 25V AC (on 600V AC Drives)

Max:

255V AC (on 230V AC Drives); 510V AC (on 460V AC Drives); 637.5V AC (on 600V AC Drives)

Display:

1V AC

Advertising