Environmental specifications – Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual

Page 156

Advertising
background image

156

Rockwell Automation Publication 520-UM001G-EN-E - September 2014

Appendix A

Supplemental Drive Information

Environmental Specifications

EPRI

Electric Power Research Institute
Certified compliant with the following standards:

SEMI F47
IEC 61000-4-34

Lloyds Register

Not applicable

Lloyd’s Register Type Approval Certificate
12/10068(E1)

RoHS

Compliant with the European “Restriction of Hazardous Substances” Directive

The drive is also designed to meet the appropriate portions of the following specifications:

NFPA 70 - US National Electrical Code
NEMA ICS 7.1 - Safety standards for Construction and Guide for Selection, Installation and Operation of Adjustable
Speed Drive Systems.

Certifications

PowerFlex 523

PowerFlex 525

Specifications

PowerFlex 523

PowerFlex 525

Altitude:

Without derating:
With derating:

See

Current Derating Curves on page 17

for derating guidelines.

1000 m (3300 ft) max.
Up to 4000 m (13,200 ft) max., with the exception of 600V drives at 2000 m (6600 ft)
max.

Max. Surrounding Air
Temperature

Without derating:
With derating:

See

Current Derating Curves on page 17

for derating guidelines.

-20...50

°C (-4...122 °F)

-20...60

°C (-4...140 °F) or -20...70 °C (-4...158 °F) with optional Control Module Fan

kit.

Storage Temperature:

Frame A...D:
Frame E:

-40...85

°C (-40...185 °F)

-40...70 °C (-40...158 °F)

Atmosphere:

Relative Humidity:

0...95% noncondensing

Shock:
Vibration:

Complies with IEC 60068-2-27
Complies with IEC 60068-2-6:1995

Conformal Coating:

Complies with:

IEC 60721-3-3 to level 3C2 (chemical and gases only)

Surrounding Environment
Pollution Degree

Pollution Degree 1 & 2:

See

Pollution Degree Ratings According to EN 61800-5-1 on page 49

for descriptions.
All enclosures acceptable.

Sound Pressure Level
(A-weighted)

Frame A & B:
Frame C:
Frame D:
Frame E:

Measurements are taken 1 m from the drive.

Maximum 53 dBA
Maximum 57 dBA
Maximum 64 dBA
Maximum 68 dBA

IMPORTANT

Drive must not be installed in an area where the ambient atmosphere contains volatile or
corrosive gas, vapors or dust. If the drive is not going to be installed for a period of time, it must
be stored in an area where it will not be exposed to a corrosive atmosphere.

Frame
Size

Operating and Nonoperating

Nonoperating (Transportation)

Force
(Shock/Vibration)

Mounting Type

Force
(Shock/Vibration)

Mounting Type

A

15 g / 2 g

DIN rail or screw

30 g/ 2.5 g

Screw only

B

15 g / 2 g

DIN rail or screw

30 g/ 2.5 g

Screw only

C

15 g / 2 g

DIN rail or screw

30 g/ 2.5 g

Screw only

D

15 g / 2 g

Screw only

30 g/ 2.5 g

Screw only

E

15 g / 1.5 g

Screw only

30 g/ 2.5 g

Screw only

Advertising
This manual is related to the following products: