A574, Advanced program group (continued) – Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual

Page 129

Advertising
background image

Rockwell Automation Publication 520-UM001G-EN-E - September 2014

129

Programming and Parameters

Chapter 3

Advanced Program Group (continued)

A572 [Speed Ratio]

Stop drive before changing this parameter.

Scales the drive speed command.

Values

Default:

1.00

Min/Max:

0.01/99.99

Display:

0.01

A573 [Mtr Options Cfg]

PowerFlex 525 only.

(With FRN 2.xx and later.)
Sets the configuration of the motor option.

Values

Default:

11

Min/Max:

00/11

Display:

00

PF 525

1 = Enabled, 0 = Disabled

Jerk Select

Digit 1

ZeroSpd Slip

Digit 2

Not Used

Not Used

Not Used

Options

Description

Jerk Select

Limits the rate of change to the velocity reference for improved current limiting. Set to
0 “Disabled” for positioning type applications with fast Accel or Decel times.

ZeroSpd Slip

Sets slip compensation to 0.0 Hz when the following conditions are met:
Commanded speed = 0.00 Hz
Status of drive = “At speed”
ZeroSpd Slip = 1 “Enabled”

A574 [RdyBit Mode Cfg]

Related Parameter(s):

d392

Stop drive before changing this parameter.

PowerFlex 525 only.

(With FRN 3.xxx and later.)
Determines which Stop conditions causes the drive’s Ready bit (Network Logic Status bit 1) to go low (0). A reset or power cycle is required after selection is made.

Options

0 “Standard” (Default)

1 “Enhanced”

PF 525

Ready Bit Status

(1)

(1) 1 = Active, 0 = Inactive

Stop Conditions

Standard

Enhanced

Drive fault

0

0

Stop digital input terminal 01/11 open

1

0

Holding down the drive’s keypad or the Remote DSI HIM Stop button

1

0

Stop commanded through Comms (Stop bit = 1)

1

0

Software (SW) Enable digital input terminal open

1

0

Safe-Torque-Off (STO) condition with value of t105 [Safety Open En] set to 1 “FaultDisabled”

0

0