209

Encoder/Pulse Train Usage and Position StepLogic Application

Appendix E

Note: Incremental move commands will cause the drive to move the amount
specified based on the current position. Absolute commands are always with
reference to “Home”.

A565

[Pos Reg Filter] provides a low pass filter at the input of the position

regulator.

A566

[Pos Reg Gain] is a single adjustment for increasing or decreasing the

responsiveness of the position regulator. For faster response, the filter should be
reduced and/or the gain should be increased. For smoother response with less

Logic for next step

Digit 1

Logic to jump to a different step

Digit 2

Different step to jump

Digit 3

Step settings

Digit 4

Not Used

Velocity Control Settings (Digit 4)

Required
Setting

Accel/Decel
Param. Used

StepLogic
Output State

Commanded
Direction

0

Accel/Decel 1

Off

FWD

1

Accel/Decel 1

Off

REV

2

Accel/Decel 1

Off

No Output

3

Accel/Decel 1

On

FWD

4

Accel/Decel 1

On

REV

5

Accel/Decel 1

On

No Output

6

Accel/Decel 2

Off

FWD

7

Accel/Decel 2

Off

REV

8

Accel/Decel 2

Off

No Output

9

Accel/Decel 2

On

FWD

A

Accel/Decel 2

On

REV

b

Accel/Decel 2

On

No Output

Positioning Settings (Digit 4)

Required
Setting

Accel/Decel
Param. Used

StepLogic
Output State

Direction
From Home

Type of
Command

0

Accel/Decel 1

Off

FWD

Absolute

1

Accel/Decel 1

Off

FWD

Incremental

2

Accel/Decel 1

Off

REV

Absolute

3

Accel/Decel 1

Off

REV

Incremental

4

Accel/Decel 1

On

FWD

Absolute

5

Accel/Decel 1

On

FWD

Incremental

6

Accel/Decel 1

On

REV

Absolute

7

Accel/Decel 1

On

REV

Incremental

8

Accel/Decel 2

Off

FWD

Absolute

9

Accel/Decel 2

Off

FWD

Incremental

A

Accel/Decel 2

Off

REV

Absolute

b

Accel/Decel 2

Off

REV

Incremental

C

Accel/Decel 2

On

FWD

Absolute

d

Accel/Decel 2

On

FWD

Incremental

E

Accel/Decel 2

On

REV

Absolute

F

Accel/Decel 2

On

REV

Incremental

Settings (Digit 3)

Setting Description

0

Jump to Step 0

1

Jump to Step 1

2

Jump to Step 2

3

Jump to Step 3

4

Jump to Step 4

5

Jump to Step 5

6

Jump to Step 6

7

Jump to Step 7

8

End Program (Normal Stop)

9

End Program (Coast to Stop)

A

End Program and Fault (F2)

Settings (Digit 2 and 1)

Setting Description

0

Skip Step (Jump Immediately)

1

Step Based on [Stp Logic Time x]

2

Step if “Logic In 1” is Active

3

Step if “Logic In 2” is Active

4

Step if “Logic In 1” is Not Active

5

Step if “Logic In 2” is Not Active

6

Step if either “Logic In 1” or “Logic In 2” is Active

7

Step if both “Logic In 1” and “Logic In 2” are Active

8

Step if neither “Logic In 1” nor “Logic In 2” is Active

9

Step if “Logic In 1” is Active and “Logic In 2” is Not Active

A

Step if “Logic In 2” is Active and “Logic In 1” is Not Active

b

Step after [Stp Logic Time x] and “Logic In 1” is Active

C

Step after [Stp Logic Time x] and “Logic In 2” is Active

d

Step after [Stp Logic Time x] and “Logic In 1” is Not Active

E

Step after [Stp Logic Time x] and “Logic In 2” is Not Active

F

Do Not Step/Ignore Digit 2 Settings

TIP

Use the Wizard in Connected Components Workbench to simplify setup instead
of manually configuring the parameters.