Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual

Page 142

Advertising
background image

142

Rockwell Automation Publication 520-UM001G-EN-E - September 2014

Chapter 3

Programming and Parameters

Parameter Name

No.

Parameter Name

No.

Parameter Name

No.

Opt Data Out 1

165

Position Status

(1)

387

Shear Pin 2 Time

(1)

489

Opt Data Out 2

166

Positioning Mode

(1)

558

Shear Pin2 Level

(1)

488

Opt Data Out 3

167

Power Loss Mode

548

Skip Freq Band 1

449

Opt Data Out 4

168

Power Saved

018

Skip Freq Band 2

451

Opto Out Logic

(1)

075

Preset Freq 0

410

Skip Freq Band 3

(1)

453

Opto Out1 Level

(1)

070

Preset Freq 1

411

Skip Freq Band 4

(1)

455

Opto Out1 Sel

(1)

069

Preset Freq 2

412

Skip Frequency 1

448

Opto Out2 Level

(1)

073

Preset Freq 3

413

Skip Frequency 2

450

Opto Out2 Sel

(1)

072

Preset Freq 4

414

Skip Frequency 3

(1)

452

Out Phas Loss En

557

Preset Freq 5

415

Skip Frequency 4

(1)

454

Output Current

003

Preset Freq 6

416

Sleep Level

101

Output Freq

001

Preset Freq 7

417

Sleep Time

102

Output Power

017

Preset Freq 8

(1)

418

Sleep-Wake Sel

100

Output Powr Fctr

381

Preset Freq 9

(1)

419

Slip Hz Meter

375

Output RPM

015

Preset Freq 10

(1)

420

Speed Feedback

376

Output Speed

016

Preset Freq 11

(1)

421

Speed Ratio

572

Output Voltage

004

Preset Freq 12

(1)

422

Speed Reference1

047

P Jump

570

Preset Freq 13

(1)

423

Speed Reference2

049

PID 1 Deadband

465

Preset Freq 14

(1)

424

Speed Reference3

051

PID 1 Diff Rate

463

Preset Freq 15

(1)

425

Speed Reg Sel

(1)

509

PID 1 Fdback Sel

460

Process Disp Hi

482

Stall Fault Time

492

PID 1 Integ Time

462

Process Disp Lo

481

Start At PowerUp

543

PID 1 Invert Err

467

Process Display

010

Start Boost

531

PID 1 Preload

466

Program Lock

552

Start Source 1

046

PID 1 Prop Gain

461

Program Lock Mod

553

Start Source 2

048

PID 1 Ref Sel

459

Pulse In Scale

537

Start Source 3

050

PID 1 Setpoint

464

Purge Frequency

433

Status @ Fault 1

661

PID 1 Trim Hi

456

PWM Frequency

440

Status @ Fault 2

662

PID 1 Trim Lo

457

RdyBit Mode Act

392

Status @ Fault 3

663

PID 1 Trim Sel

458

RdyBit Mode Cfg

574

Status @ Fault 4

664

PID1 Fdbk Displ

383

Relay 1 Off Time

080

Status @ Fault 5

665

PID1 Setpnt Disp

384

Relay 1 On Time

079

Status @ Fault 6

(1)

666

PID 2 Deadband

(1)

477

Relay Out1 Level

077

Status @ Fault 7

(1)

667

PID 2 Diff Rate

(1)

475

Relay Out1 Sel

076

Status @ Fault 8

(1)

668

PID 2 Fdback Sel

(1)

472

Relay 2 Off Time

(1)

085

Status @ Fault 9

(1)

669

PID 2 Integ Time

(1)

474

Relay 2 On Time

(1)

084

Status @ Fault10

(1)

670

PID 2 Invert Err

(1)

479

Relay Out2 Level

(1)

082

Step Units 0

(1)

200

PID 2 Preload

(1)

478

Relay Out2 Sel

(1)

081

Step Units 1

(1)

202

PID 2 Prop Gain

(1)

473

Reset Meters

555

Step Units 2

(1)

204

PID 2 Ref Sel

(1)

471

Reset to Defalts

053

Step Units 3

(1)

206

PID 2 Setpoint

(1)

476

Reverse Disable

544

Step Units 4

(1)

208

PID 2 Trim Hi

(1)

468

RS485 Data Rate

123

Step Units 5

(1)

210

PID 2 Trim Lo

(1)

469

RS485 Format

127

Step Units 6

(1)

212

PID 2 Trim Sel

(1)

470

RS485 Node Addr

124

Step Units 7

(1)

214

PID2 Fdbk Displ

(1)

385

S Curve %

439

Stop Mode

045

PID2 Setpnt Disp

(1)

386

Safety Open En

(1)

105

Stp Logic 0

(1)

180

Pos Reg Filter

(1)

565

Shear Pin 1 Time

487

Stp Logic 1

(1)

181

Pos Reg Gain

(1)

566

Shear Pin1 Level

486

Stp Logic 2

(1)

182

(1) Parameter is specific to PowerFlex 525 drives only.