62

Rockwell Automation Publication 520-UM001G-EN-E - September 2014

Chapter 2

Start Up

P040

[Autotune]

0/2

0 = “Ready/Idle”
1 = “Static Tune”
2 = “Rotate Tune”

0

Enables a static (not spinning) or dynamic (motor
spinning) autotune.

P041

[Accel Time 1]

0.00/600.00 s

0.01 s

10.00 s

Sets the time for the drive to accel from 0 Hz to
[Maximum Freq].

P042

[Decel Time 1]

0.00/600.00 s

0.01 s

10.00 s

Sets the time for the drive to decel from [Maximum
Freq] to 0 Hz.

P043

[Minimum Freq]

0.00/500.00 Hz

0.01 Hz

0.00 Hz

Sets the lowest frequency the drive outputs.

P044

[Maximum Freq]

0.00/500.00 Hz

0.01 Hz

60.00 Hz

Sets the highest frequency the drive outputs.

P045

[Stop Mode]

0/11

0 = “Ramp, CF”

(1)

1 = “Coast, CF”

(1)

2 = “DC Brake, CF”

(1)

3 = “DCBrkAuto,CF”

(1)

4 = “Ramp”
5 = “Coast”
6 = “DC Brake”
7 = “DC BrakeAuto”
8 = “Ramp+EM B,CF”

(1)

9 = “Ramp+EM Brk”
10 = “PointStp,CF”

(1)

11 = “PointStop”

0

Stop command for normal stop.
Important: I/O Terminal 01 is always a stop input.
The stopping mode is determined by the drive
setting.
Important: The drive is shipped with a jumper
installed between I/O Terminals 01 and 11. Remove
this jumper when using I/O Terminal 01 as a stop or
enable input.

(1) Stop input also clears active fault.

P046,
P048,
P050

[Start Source 1]

1/5

1 = “Keypad”

(1)

2 = “DigIn TrmBlk”

(2)

3 = “Serial/DSI”
4 = “Network Opt”
5 = “Ethernet/IP”

(3)

P046 = 1
P048 = 2
P050 = 3 (PowerFlex 523)

5 (PowerFlex 525)

Sets the default control scheme used to start the
drive unless overriden by P048 [Start Source 2] or
P050 [Start Source 3].

(1) When active, the Reverse key is also active unless

disabled by A544 [Reverse Disable].

(2) If “DigIn TrmBlk” is selected, ensure that the digital

inputs are properly configured.

(3) Setting is specific to PowerFlex 525 drives only.

P047,
P049,
P051

[Speed Reference1]

1/16

1 = “Drive Pot”
2 = “Keypad Freq”
3 = “Serial/DSI”
4 = “Network Opt”
5 = “0-10V Input”
6 = “4-20mA Input”
7 = “Preset Freq”
8 = “Anlg In Mult”

(1)

9 = “MOP”
10 = “Pulse Input”
11 = “PID1 Output”
12 = “PID2 Output”

(1)

13 = “Step Logic”

(1)

14 = “Encoder”

(1)

15 = “Ethernet/IP”

(1)

16 = “Positioning”

(1)

P047 = 1
P049 = 5
P051 = 3 (PowerFlex 523)

15 (PowerFlex 525)

Sets the default speed command of the drive unless
overridden by P049 [Speed Reference2] or P051
[Speed Reference3].

(1) Setting is specific to PowerFlex 525 drives only.

P052

[Average kWh Cost]

0.00/655.35

0.01

0.00

Sets the average cost per kWh.

P053

[Reset To Defalts]

0/3

0 = “Ready/Idle”
1 = “Param Reset”
2 = “Factory Rset”
3 = “Power Reset”

0

Resets parameters to their factory defaults values.
After a Reset command, the value of this parameter
returns to zero.

= Stop drive before changing this parameter.
= Parameter is specific to PowerFlex 525 drives only.

No.

Parameter

Min/Max

Display/Options

Default

PF 525