Encoder and position feedback – Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual

Page 211

Advertising
background image

Rockwell Automation Publication 520-UM001G-EN-E - September 2014

211

Encoder/Pulse Train Usage and Position StepLogic Application

Appendix E

point too quickly it will then reverse direction at 1/10th

A562

[Find Home Freq]

to the point where the Home Limit switch reactivates. Approximately one second
after the routine finds home the drive will stop. Alternately, the “Find Home
Freq” and/or “Home Limit” bits in

A560

[Enh Control Word] can be activated

instead of utilizing a digital input. The inputs or bits should be returned to
inactive after the routine is complete.

Encoder and Position
Feedback

d376

[Speed Feedback] indicates the measured speed feedback or the calculated

speed feedback when no feedback device is selected. Parameter d376 [Speed
Feedback] is the number value to the left of the decimal (whole number) and
d377 [Speed Feedback F] is the value to the right of the decimal (the portion less
than 1).

d378

[Encoder Speed] indicates the measured speed of the feedback device. This

is useful if the encoder is not used for motor speed control. However, the encoder
must be used for some purpose in order for d378 [Encoder Speed] to indicate a
value. Parameter d378 [Encoder Speed] is the number value to the left of the
decimal (whole number) and d379 [Encoder Speed F] is the number to the right
of the decimal (the portion less than 1).

d388

,

d389

[Units Traveled x] indicate the current position of the system in

terms of units away from Home. Parameter d388 [Units Traveled H] is the
number value to the left of the decimal (whole number) and d389 [Units
Traveled L] is the number to the right of the decimal (the portion less than 1).

d387

[Position Status] indicates the status of the positioning functions. The

indication bits are:

Bit 0 “Dir Positive”

indicates the current direction the drive has moved

from Home.

Bit 1 “At Position”

indicates whether the drive is at its commanded

position. If the drive is within

A564

[Encoder Pos Tol] of the commanded

position, this bit will be active.

Bit 2 “At Home”

indicates whether the drive is at Home. If the drive is

within

A564

[Encoder Pos Tol] of “Home”, this bit will be active.

Bit 3 “Drive Homed”

indicates whether the drive has been homed since

power-up. This bit will be active once the drive has been homed either
manually or automatically. It will remain active until the next power down.

IMPORTANT

After the position is reached the drive will stop. If the Find Home is removed
before the homing is complete, the drive will begin running the position
routine without the proper home. In this case Home will not be reset and the
position will be in relation to the power up position.

Advertising
This manual is related to the following products: