Chapter 5 Using the LCD

1. On the Main Menu screen, select Monitoring by using the Up and Down

keys on the LCD keypad.

2. Then, press the OK key on the LCD keypad. The File Number prompt is

displayed.

3. If Integer is selected, as shown in

step 2

, press the OK key. If not selected,

press the Down key to select it and then press the OK key.

4. The current data value (ON) of the L9:0 word is displayed. Note that the

target word "0", which is at the right "L9:", is flashing, which means the
cursor is at the target word position.

5. We will change the data value of the L9:0 word to the negative decimal

value -1300. First, press OK to move the cursor to the data value position.
Then, the last digit of "+0000000000" will be flashing, which means the
cursor is at the data value position.