Appendix F MicroLogix 1400 Distributed Network Protocol (DNP3)

227

Read Only

INT

1

1

Support for counter events

1

228

Read Only

UINT

4

2

Max counter index

256*2

229

Read Only

UINT

4

2

Number of counter points

0…256*2

230

Read Only

INT

1

1

Support for frozen analog
inputs

0

231

Read Only

INT

1

1

Support for analog input
events

1

232

Read Only

UINT

4

2

Maximum analog input index

256*3

233

Read Only

UINT

4

2

Number of analog input
points

0…256*3

234

Read Only

INT

1

1

Support for double-bit binary
input events

1

235

Read Only

UINT

4

2

Maximum double-bit binary
input index

256*8

236

Read Only

UINT

4

2

Number of double-bit binary
input points

0…256*8

237

Read Only

INT

1

1

Support for binary input
events

1

238

Read Only

UINT

4

2

Max binary input index

256*16

239

Read Only

UINT

4

2

Number of binary input
points

0…256*16

240

Read Only

UINT

4

2

Max transmit fragment size

2048 (27…2048). When this value is written
to the controller, the communication
configuration file is changed to this value.

241

Read Only

UINT

4

2

Max receive fragment size

2048

242

Read Only

VSTR

length of the
string value

length of the
string value

Device manufacturer's
software version

This variation returns firmware FRN. "FRN
1.00".
Supported ranges: "FRN x.yy", "FRN x.yyy",
"FRN xx.yy" or "FRN xx.yyy" where x, xx is 0 ~
99 and yy, yyy 00 ~ 999.
For example, "FRN 1.00", "FRN 1.05", "FRN
12.05", "FRN 102.27" or "FRN 103.117".

243

Read Only

VSTR

length of the
string value

length of the
string value

Device manufacturer's
hardware version

This variation returns
hardware series and
revision of the
controller. "HW SER
A/REV 01".

This variation returns
hardware series and
revision of the
controller. "HW SER
A/REV 03".

Supported ranges: "HW SER x/REV yy" where
x is A ~ F and yy is 00 ~ 31.
For example, "HW SER A/REV 01", "HW SER
B/REV 03", or "HW SER C/REV 31".

244

-

-

-

-

Reserved for future
assignment

-

-

245

Read
/Write

VSTR

length of the
string value,
max 255
bytes

length of the
string value,
max 255
bytes

User-assigned location name

"". Non-NULL terminated.

Object Group 0, Variations for Attribute Set 0

Variation

Read
/Write

Attribute
Data Type

Length in
Bytes
(Series A)

Max Length
in Bytes
(Series B)

Description

Value (Series A)

Value (Series B)