Rockwell Automation Publication 1766-UM001H-EN-P - May 2014
55
Wire Your Controller Chapter 3
Figure 31 - 1762-IF4 Terminal Block Layout
Figure 32 - Differential Sensor Transmitter Types
TIP
Grounding the cable shield at the module end only usually provides
sufficient noise immunity. However, for best cable shield
performance, earth ground the shield at both ends, using a 0.01µF
capacitor at one end to block AC power ground currents, if necessary.
IN 1 (+)
IN 0 (+)
IN 1 (-)
IN 0 (-)
IN 3 (+)
IN 2 (+)
IN 3 (-)
IN 2 (-)
COM
COM
Commons internally connected.
IN 0 (+)
IN 0 (-)
IN 3 (+)
IN 3 (-)
IN 2 (+)
IN 2 (-)
COM
IN 1 (-)
IN 1 (+)
COM
Analog Sensor