Implementation table – Rockwell Automation 1766-Lxxxx MicroLogix 1400 Programmable Controllers User Manual User Manual

Page 354

Advertising
background image

314

Rockwell Automation Publication 1766-UM001H-EN-P - May 2014

Appendix F MicroLogix 1400 Distributed Network Protocol (DNP3)

Implementation Table

MicroLogix 1400 supports DNP3 Certification Subset Level 2.

The implementation table in this section identifies which object groups and
variations, function codes and qualifiers the device supports in both requests and
responses. The Request and Response columns identify all requests and responses

Request

14 (0x0E)

FC_WARM_RESTART

No

MicroLogix 1400 parses

Request

15 (0x0F)

FC_INITIALIZE_DATA

No

Obsolete

Request

16 (0x10)

FC_INITIALIZE_APPL

Yes

MicroLogix 1400 parses. Clears fault and changes the
controller mode to Remote Program. See Starting and
Stopping User Programs (Mode Change) via DNP3 Network on
page 294.

Request

17 (0x11)

FC_START_APPL

Yes

MicroLogix 1400 parses. Clears fault and changes the
controller mode to Remote Run. See Starting and Stopping
User Programs (Mode Change) via DNP3 Network on page
294.

Request

18 (0x12)

FC_STOP_APPL

Yes

MicroLogix 1400 parses. Changes the controller mode to
Remote Program. See Starting and Stopping User Programs
(Mode Change) via DNP3 Network on page 294.

Request

19 (0x13)

FC_SAVE_CONFIG

No

Deprecated.

Request

20 (0x14)

FC_ENABLE_UNSOLICITED

Yes

MicroLogix 1400 parses

Request

21 (0x15)

FC_DISABLE_UNSOLICITED

Yes

MicroLogix 1400 parses

Request

22 (0x16)

FC_ASSIGN_CLASS

No

Request

23 (0x17)

FC_DELAY_MEASURE

Yes

MicroLogix 1400 parses. Used for non-LAN

Request

24 (0x18)

FC_RECORD_CURRENT_TIME

No

MicroLogix 1400 parses.Used for LAN

Request

25 (0x19)

FC_OPEN_FILE

Yes

MicroLogix 1400 parses

Request

26 (0x1A)

FC_CLOSE_FILE

Yes

MicroLogix 1400 parses

Request

27 (0x1B)

FC_DELETE_FILE

Yes

MicroLogix 1400 parses

Request

28 (0x1C)

FC_GET_FILE_INFO

No

MicroLogix 1400 parses

Request

29 (0x1D)

FC_AUTHENTICATE_FILE

Yes

MicroLogix 1400 parses

Request

30 (0x1E)

FC_ABORT_FILE

No

MicroLogix 1400 parses

Request

31 (0x1F)

FC_ACTIVATE_CONFIG

No

MicroLogix 1400 parses

Request

32 (0x20)

FC_AUTHENTICATE_REQ

No

MicroLogix 1400 parses

Request

33 (0x21)

FC_AUTHENTICATE_ERR

No

MicroLogix 1400 parses

34 (0x22) to
128 (0x80)

No

Reserved.

Response

129 (0x81)

FC_RESPONSE

Yes

MicroLogix 1400 sends

Response

130 (0x82)

FC_UNSOLICITED_RESPONSE

Yes

MicroLogix 1400 sends

Response

131 (0x83)

FC_AUTHENTICATE_RESP

No

MicroLogix 1400 sends

132 (0x84) to
255 (0xFF)

No

Reserved.

Function Codes for MicroLogix 1400 Series B Controllers

Message
Type

Function
Code

Name

MicroLogix
1400 Support

Description

Advertising