Rockwell Automation 1766-Lxxxx MicroLogix 1400 Programmable Controllers User Manual User Manual

Page 361

Advertising
background image

Rockwell Automation Publication 1766-UM001H-EN-P - May 2014

321

MicroLogix 1400 Distributed Network Protocol (DNP3) Appendix F

20

1

Counter - 32-bit with flag

7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)

06 (no range, or all)

20

2

Counter - 16-bit with flag

1 (read)

00, 01 (start-stop)
06 (no range, or all)

129 (response)

00, 01 (start-stop)

20

2

Counter - 16-bit with flag

7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)

06 (no range, or all)

20

5

Counter - 32-bit without flag

1 (read)

00, 01 (start-stop)
06 (no range, or all)

129 (response)

00, 01 (start-stop)

20

5

Counter - 32-bit without flag

7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)

06 (no range, or all)

20

6

Counter - 16-bit without flag

1 (read)

00, 01 (start-stop)
06 (no range, or all)

129 (response)

00, 01 (start-stop)

20

6

Counter - 16-bit without flag

7 (freeze)
8 (freeze noack)
9 (freeze clear)
10 (frz. cl. noack)

06 (no range, or all)

21

0

Frozen Counter - Any Variation

1 (read)

00, 01 (start-stop)

06 (no range, or all)

21

1

Frozen Counter - 32-bit with flag 1 (read)

06 (no range, or all)

129 (response)

00, 01 (start-stop)

21

2

Frozen Counter - 16-bit with flag 1 (read)

00, 01 (start-stop)
06 (no range, or all)

129 (response)

00, 01 (start-stop)

21

5

Frozen Counter - 32-bit with flag
and time

1 (read)

00, 01 (start-stop)
06 (no range, or all)

129 (response)

00, 01 (start-stop)

21

6

Frozen Counter - 16-bit with flag
and time

1 (read)

00, 01 (start-stop)
06 (no range, or all)

129 (response)

00, 01 (start-stop)

21

9

Frozen Counter - 32-bit without
flag

1 (read)

00, 01 (start-stop)
06 (no range, or all)

129 (response)

00, 01 (start-stop)

21

10

Frozen Counter - 16-bit without
flag

1 (read)

00, 01 (start-stop)
06 (no range, or all)

129 (response)

00, 01 (start-stop)

22

0

Counter Event - Any Variation

1 (read)

06 (no range, or all)
07, 08 (limited qty)

22

1

Counter Event - 32-bit with flag

1 (read)

06 (no range, or all)
07, 08 (limited qty)

129 (response)
130 (unsol. resp)

17, 28 (index)

22

2

Counter Event - 16-bit with flag

1 (read)

06 (no range, or all)
07, 08 (limited qty)

129 (response)
130 (unsol. resp)

17, 28 (index)

22

5

Counter Event - 32-bit with flag
and time

1 (read)

06 (no range, or all)
07, 08 (limited qty)

129 (response)
130 (unsol. resp)

17, 28 (index)

22

6

Counter Event - 16-bit with flag
and time

1 (read)

06 (no range, or all)
07, 08 (limited qty)

129 (response)
130 (unsol. resp)

17, 28 (index)

23

0

Frozen Counter Event - Any
Variation

1 (read)

06 (no range, or all)
07, 08 (limited qty)

Implementation Table for Series B controllers

DNP Object Group & Variation

Request
DNP3 Master may issue
MicroLogix 1400 must parse

Response
DNP3 Master must parse
MicroLogix 1400 may issue

Group
Num

Var Num Description

Function Codes
(dec)

Qualifier Codes (hex)

Function Codes
(dec)

Qualifier Codes
(hex)

Advertising