Event reporting, Generating events – Rockwell Automation 1766-Lxxxx MicroLogix 1400 Programmable Controllers User Manual User Manual

Page 317

Advertising
background image

Rockwell Automation Publication 1766-UM001H-EN-P - May 2014

277

MicroLogix 1400 Distributed Network Protocol (DNP3) Appendix F

Event Reporting

This section covers how to generate DNP3 events from DNP3 Data Objects and
how to report the generated events by polled response or unsolicited response.

Generating Events

The MicroLogix 1400 has a separate buffer area that you can use to log DNP3
events internally.

246

Read
/Write

VSTR

length of the
string value,
max 255
bytes

length of the
string value,
max 255
bytes

User-assigned ID
code/number

"". Non-NULL terminated.

247

Read
/Write

VSTR

length of the
string value,
max 255
bytes

length of the
string value,
max 255
bytes

User-assigned device name

"". Non-NULL terminated.

248

Read Only

VSTR

12

12

Device serial number

This variation returns Ethernet MAC ID.
"0000BCxxxxxx".

249

Read Only

VSTR

6

6

DNP subset and
conformance

This variation returns
Subset level and Test
procedure version.
"2:2008".

This variation returns
Subset level and Test
procedure version.
"2:2009".

250

Read Only

VSTR

length of the
string value

length of the
string value

Device manufacturer's
product name and model

This variation returns
Catalog Number and
OS Series of the
controller.
"1766-L32BWA SER
A".

This variation returns
Catalog Number and
OS Series of the
controller.
"1766-L32BWA SER
B".

Supported ranges: "1766-L32xxxa SER y"
where xxxa is BWA, AWA, BXB, BWAA,
AWAA, or BXBA and y is A ~ F.
For example, "1766-L32BWA SER A",
"1766-L32AWA SER B", "1766-L32BXB SER
C", or "1766-L32BWAA SER A".

251

-

-

-

-

Reserved for future
assignment

-

-

252

Read Only

VSTR

13

19

Device manufacturer's name

This variation returns
the Company name.
"Allen-Bradley".

This variation returns
the Company name.
"Rockwell
Automation" for
DNP3.

253

Read Only

-

-

-

Reserved for future
assignment

-

-

254

Read Only

-

-

-

Non-specific all attributes
request

This variable returns all of the variations in
this group except this variation.

255

Read Only

-

-

-

List of attribute variations

This variation returns the R/W property for
each variation. From g0v211 to g0v253.
0 for Read Only
1 for Read or Write

Object Group 0, Variations for Attribute Set 0

Variation

Read
/Write

Attribute
Data Type

Length in
Bytes
(Series A)

Max Length
in Bytes
(Series B)

Description

Value (Series A)

Value (Series B)

Advertising
This manual is related to the following products: