3 Functions

Issue 10/06

MICROMASTER 440 Operating Instructions

210

6SE6400-5AW00-0BP0

NOTE

¾

The switch-on threshold V

DC chopper

of the dynamic resistor braking is dependent

on P1254
V

DC chopper

(P1254 = 0)

V

DC chopper

(P1254

0).

a) Auto-detect circuit enabled (P1254 = 1):

- U

DC-Chopper

(P1254 = 1) is automatically calculated when the drive

inverter runs-up - i.e. after the line supply voltage has been
connected.

- Using the auto-detect function, the U

DC-Chopper

threshold automatically

adapts itself to the line supply voltage at the particular installation
location.

b) Auto-detect function disabled (P1254 = 0):

-

0210

P

2

13

.

1

U

Chopper

,

DC

=

- The

U

DC-Chopper

threshold is immediately re-calculated after entering

P0210

- P0210 must be adapted to the particular installation location

¾

External braking modules (chopper units) including braking resistor can be used

with all of the sizes, FS FX and FS GX. When engineering the system, the
particular braking module / resistor must be taken into consideration.

WARNING
¾

Braking resistors, which are to be mounted on MICROMASTER 440, must be

designed so that they can tolerate the power dissipated.

¾

If an unsuitable braking resistor is used there is a danger of fire and that the

associated drive inverter will be significantly damaged.

¾

The chopper control, integrated in the drive converter is designed for the

braking resistor value assigned in Catalog DA51.2,
e.g.: MICROMASTER 440

6SE6440-2UD23-0BA1

brake

resistor

6SE6400-4BD12-0BA0

brake resistor value

160

¾

A brake resistor with a lower resistance value will destroy the drive converter.

In this case, an external braking unit must be used.

¾

When operational, the temperature of braking resistors increases – do not

touch ! Ensure that there is sufficient clearance around the unit and there is
adequate ventilation.

¾

A temperature protection switch must be used to protect the units against

overheating.