Watson-Marlow MM440 User Manual

Page 56

Advertising
background image

3 Functions

Issue 10/06

MICROMASTER 440 Operating Instructions

56

6SE6400-5AW00-0BP0

The interrelationship between access level P0003 and the grouping P0004 is
schematically shown in Fig. 3-3.

P0004 = 2

P0004 = 3

P0004 = 7

P0004 = 8

P0004 = 10

P0004 = 12

P0004 = 13

P0004 = 20

P0004 = 21

P0004 = 22

P0004 = 0

P0004 = 2

P0004 = 2, P0003 = 1

P0004 = 2, P0003 = 2

P0004 = 2, P0003 = 4

P0004 = 2, P0003 = 3

(no filter function)
allows direct access
to the parameters.
For BOP and AOP
depending on the
selected access level

Parameters level 1
concerning the inverter unit

Parameters level 1, 2 and 3
concerning the inverter unit

Inverter Unit

Parameters level 1 and 2

concerning the inverter unit

Parameters level 1, 2, 3 and 4

concerning the inverter unit

Inverter Unit

Motor Data

PID Controller

Alarms, Warnings &
Monitoring

Motor Control
P1300 ... P1799

Drive Features
P1200 ... P1299

Setpoint Channel &
Ramp Generator
P1000 ... P1199

Speed sensor
P0400 ... P0499

Commands and
Digital I/O
P0700 ... P0749
P0800 ... P0899

Communication
P2000 ... P2099

P0004 = 5

P0004 = 4

Technology
Application / units
P0400 ... P0499

Analogue I/O
P0750 ... P0799

P0200 ... P0299

P0300 ... P0399
P0600 ... P0699

P0003 = 1

P0003 = 2

P0003 = 3

P0003 = 4

P0003 = 1
2
3
4

Standard
Extended
Expert
Service

User access level

Fig. 3-3

Parameter grouping / access