3 Functions

Issue 10/06

MICROMASTER 440 Operating Instructions

222

6SE6400-5AW00-0BP0

Table 3-35

Partial excerpt of monitoring functions / messages

Functions / states

Parameter / bit number

Function chart

Drive ready

52.0

-

Drive ready to run

52.1

-

Drive running

52.2

-

Drive fault active

52.3

-

OFF2 active

52.4

-

OFF3 active

52.5

-

On inhibit active

52.6

-

Drive warning active

52.7

-

Deviation setpoint – actual value

52.8

-

PZD control

52.9

-

Maximum frequency reached

52.A

-

Warning: Motor current limit

52.B

-

Motor holding brake active

52.C

-

Motor overload

52.D

-

Motor runs right

52.E

-

Drive inverter overload

52.F

-

DC brake active

53.0

-

Ramping finished

53.9

-

PID output R2294 == P2292 (PID_min)

53.A

FP5100

PID output R2294 == P2291 (PID_max)

53.B

FP5100

Download data set 0 from AOP

53.E

-

Download data set 0 from AOP

53.F

-

|f_act| > P1080 (f_min)

53.2 2197.0

FP4100

|f_act| <= P2155 (f_1)

53.5 2197.1

FP4110

|f_act| > P2155 (f_1)

53.4 2197.2

FP4110

f_act > zero

2197.3

FP4110

f_act >= setpoint (f_set)

53.6 2197.4

-

|f_act| >= P2167 (f_off)

53.1 2197.5

FP4100

|f_act| > P1082 (f_max)

2197.6

-

f_act == setpoint (f_set)

2197.7

FP4110

i_act r0068 >= P2170

53.3 2197.8

FP4100

Approx. Vdc_act < P2172

53.7 2197.9

FP4110

Approx. Vdc_act > P2172

53.8 2197.A

FP4110

No-load operation

2197.B

-

|f_act| <= P2157 (f_2)

2198.0

-

|f_act| > P2157 (f_2)

2198.1

-

|f_act| <= P2159 (f_3)

2198.2

-

|f_act| > P2159 (f_3)

2198.3

-

|f_set| < P2161 (f_min_set)

2198.4

-

f_set > 0

2198.5

-

Motor blocked

2198.6

-

Motor stalled

2198.7

-

|i_act r0068| < P2170

2198.8

FP4100

|m_act| > P2174 & setpoint reached

2198.9

-

|m_act| > P2174

2198.A

-

Load torque monitoring: Warning

2198.B

-

Load torque monitoring: Fault

2198.C

-