Watson-Marlow MM440 User Manual

Page 264

Advertising
background image

5 MICROMASTER 440 specifications

Issue 10/06

MICROMASTER 440 Operating Instructions

264

6SE6400-5AW00-0BP0

Table 5-2

Dimensions, required cooling air flow and tightening torques for power terminals

Frame

Size

Dimensions

Required cooling air flow

Tightening torque for

power connections

mm

73

× 173 × 149

l/s 4.8 Nm 1.1

A

WxHxD

inch

2.87

× 6.81 × 5.87

CFM 10.2

mm

149

× 202 × 172

l/s 24 Nm 1.5

B

WxHxD

inch

5.87

× 7.95 × 6.77

CFM 51

mm

185

× 245 × 195

l/s 54.9 Nm 2.25

C

WxHxD

inch

7.28

× 9.65 × 7.68

CFM 116.3

mm

275

× 520 × 245

l/s

2

× 54.9

Nm 10

(max.)

D

WxHxD

inch

10.82

× 20.47 × 9.65

CFM

2

× 116.3

mm

275

× 650 × 245

l/s

2

× 54.9

Nm 10

(max.)

E

WxHxD

inch

10.82

× 25.59 × 9.65

CFM

2

× 116.3

mm

350

× 850

Height with filter 1150

l/s 150 Nm

50

F

WxHxD

inch

13.78

× 33.46 × 12.60

Height with filter 45.28

CFM 317.79

mm

326

× 1400 × 356

l/s 225 Nm 25

FX

WxHxD

inch

12.80

× 55.12 × 12.83 CFM 478.13

mm

326

× 1533 × 545

l/s 440 Nm 25

GX

WxHxD

inch

12.80

× 60.35 × 21.46 CFM 935

Advertising