Watson-Marlow MM440 User Manual

Page 65

Advertising
background image

Issue 10/06

3 Functions

MICROMASTER 440 Operating Instructions

6SE6400-5AW00-0BP0

65

P0809[0] = 0
P0809[1] = 2
P0809[2] = 1

2. CDS 3. CDS

P0700
P0701
P0702
P0703
P0704

..

..

.

P2253
P2254
P2264

..

..

.

..

..

.

..

..

.

[0]

[1]

[2]

1. CDS

1. CDS
3. CDS
Start copy

Fig. 3-9

Copying from CDS

The command data sets are changed-over using the BICO parameter P0810 and
P0811, whereby the active command data set is displayed in parameter r0050
(refer to Fig. 3-10). Changeover is possible both in the "Read" as well as in the
"Run" states.

t

0

1

2

3

(0:0)

BI: CDS b0 loc/rem

P0810

(0:0)

BI: CDS bit 1

P0811

t

0

1

2

3

CO/BO: Act CtrlWd2

r0055

r0055

CO/BO: Act CtrlWd1

r0054

r0054

.15

.15

.15

.15

r0050

CDS active

Selection of CDS

Switch-over time

aprox. 4 ms

Switch-over time

aprox. 4 ms

Fig. 3-10

Changing-over CDS