1 troubleshooting with the sdp – Watson-Marlow MM440 User Manual

Page 258

Advertising
background image

4 Troubleshooting

Issue 10/06

MICROMASTER 440 Operating Instructions

258

6SE6400-5AW00-0BP0

WARNING
¾ Repairs on equipment may only be carried out by Siemens Service, by repair

centers authorized by Siemens or by qualified personnel who are thoroughly
acquainted with all the warnings and operating procedures contained in this
manual.

¾ Any defective parts or components must be replaced using parts contained in

the relevant spare parts list.

¾ Disconnect the power supply before opening the equipment for access

4.1

Troubleshooting with the SDP

Table 4-1 explains the
meaning of the various
states of the LEDs on the
SDP.

Table 4-1

Inverter conditions indicated by the LEDs on the SDP

Mains not present

Fault inverter temperature

Ready to run

Warning current limit - both

LEDs twinkling same time

Inverter fault - other than the
ones listed below

Other warnings - both LEDs

twinkling alternatively

Inverter running

Undervoltage trip /
undervoltage warning

Fault overcurrent

Drive is not in ready state

Fault overvoltage

ROM failure - Both LEDs
flashing same time

Fault motor overtemperature

RAM failure - Both LEDs
flashing alternatively

LEDs for indicating the
drive state

Off

On

approx. 0,3 s, flashing

approx. 1 s, twinkling

Advertising