Alarm and error displays, Faults – Yaskawa D1000 Series Power Regenerative Converter User Manual

Page 106

Advertising
background image

5.2 Alarms, Faults, and Errors

106

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

Alarm and Error Displays

Faults

Table 5.2

gives an overview of possible fault codes. Conditions such as overvoltages can trip faults and alarms. It is

important to distinguish between faults and alarms to determine the proper corrective actions. When the converter detects
a fault, the ALM indicator LED lights, the fault code appears on the digital operator, and the fault contact MA-MB-MC
triggers. An alarm is present if the ALM LED blinks and the fault code on the digital operator flashes. Refer to

Minor

Faults and Alarms on page 107

for a list of alarm codes.

Table 5.2 Fault Displays

Digital Operator

Display

Name

Page

Digital Operator

Display

Name

Page

LED

LCD

LED

LCD

Aov

Power Supply Overvoltage

109

FUA

AC Fuse Blowout

113

AUv

Power Supply Undervoltage

109

FUd

DC Fuse Blowout

113

bUS

Option Communication Error

109

GF

Ground Fault

113

CE

MEMOBUS/Modbus
Communication Error

109

nSE

Node Setup Error

113

CoF

Current Offset Fault

110

oC

Overcurrent

113

,

CPF00,

CPF01

Control Circuit Error

110

to

oFA00 to

oFA43

Option Card Fault (CN5-A)

114

CPF02

A/D Conversion Error

110

CPF03

Control Board Connection
Error

110

to

oFb00 to

oFb17

Option Card Fault (CN5-B)

115

CPF06

EEPROM Memory Data Error

111

CPF07

Terminal Board Connection
Error

111

to

oFC00 to

oFC55

Option Card Fault (CN5-C)

115

CPF08

Terminal Board Connection
Error

111

,

<1>

CPF11 to

CPF22

Control Circuit Error

110

oH

Heatsink Overheat

116

oH1

Overheat 1

116

CPF23

Control Board Connection
Error

111

oL2

Converter Overload

116

CPF24

Unit Capacity Detect Fault

111

oPr

Operator Connection Fault

117

to

CPF26

to

CPF35

Control Circuit Error

110

ov

Overvoltage

117

PF2

Input Power Supply Fault

117

E5

MECHATROLINK
Watchdog Timer Error

111

PF3

Input Phase Loss Detection

117

EF0

Option Card External Fault

111

SC

IGBT Short Circuit or Ground
Fault

118

to

EF1

to

EF8

External Fault
(input terminal S1 to S8)

111

SrC

Phase Order Fault

118

Uv1

Main Circuit Undervoltage

118

Err

EEPROM Write Error

112

Uv2

Control Power Supply
Undervoltage

119

Fan

Internal Fan Fault

112

Uv3

Soft Charge Circuit Fault

119

Fdv

Power Supply Frequency Fault

112

vrE

Resonance Detection

119

TOEP_C710656_07C_2_0.book 106 ページ 2015年1月9日 金曜日 午後6時23分

Advertising