C.9 MEMOBUS/Modbus Data Table

222

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

002EH

Converter Status
bit 0

1: During Run 0: During Stop

bit 2

1: During Regenerative Operation

bit 3

1: During Reset Signal Input

bit 4

1: During run (Operation Ready)

bit 5

1: Operation Ready

bit 6

1: Alarm

bit 7

1: Fault

bit 8

1: oPE Error

bit 9

1: Momentary Power Loss Ridethru 0: Recovery from Momentary Power Loss

bit A

1: ComCtrl status/NetCtrl status

bit D

1: During Active Current Limit

002FH - 0033H

Reserved

0034H

Product Code 1 [ASCII], Product Type (D1000 = DA)

0035H

Product Code 2 [ASCII], Region Code

0036H - 003CH

Reserved

003DH

Communications Error Contents

<1>

bit 0

CRC Error

bit 1

Data Length Error

bit 2

Reserved

bit 3

Parity Error

bit 4

Overrun Error

bit 5

Framing Error

bit 6

Timeout

bit 7 to bit F

Reserved

003EH - 003FH

Reserved

0040H - 004AH

Used for various monitors U1-. Refer to

U: Monitors on page 195

for parameter details.

004BH

Converter status (U1-12)
bit 0

During Run

bit 1 - bit 2

Reserved

bit 3

During Fault Reset Signal Input

bit 4

Not Used

bit 5

Operation Ready

bit 6

Alarm

bit 7

Fault

bit 8 - bit B

Reserved

bit E

ComRef status, NetRef status

bit F

ComCtrl status, NetCtrl status

004CH - 007EH

Used for various monitors U1-, U4-, U5-and U6-. Refer to

U2: Fault Trace on page 197

and

U3: Fault

History on page 199

for parameter details.

007FH

Alarm Code, Refer to

Alarm Register Contents on page 228

for alarm codes.

0080H - 0097H

Used for monitors U2-, U3-. Refer to

U: Monitors on page 195

for parameter details and Refer to

Fault Trace

Contents on page 227

for register value descriptions.

0098H

High Word of Accumulated Operation Time Monitor, 10 h units (U4-01)

0099H

Low Word of Accumulated Operation Time Monitor, 1 h units (U4-01)

009AH

High Word of Cooling Fan Operation Time Monitor (U4-03)

009BH

Low Word of Cooling Fan Operation Time Monitor (U4-03)

009CH - 00AAH

Reserved

00ABH

Converter Rated Current

00ACH - 00AFH

Reserved

Register No.