The following tables show parameters and default settings that change with o2-04 (drive model selection).

Table B.1 200 V Class Model Default Settings by Converter Model Selection

Table B.2 400 V Class Model Default Settings by Converter Model Selection

No.

Name

Unit

Default Settings

Model

2A0005 2A0010 2A0020 2A0030 2A0050 2A0065 2A0090 2A0130

o2-04

Model Selection

Hex

68

6B

6E

70

73

75

76

78

d8-01

DC Bus Voltage Reference

V

330

330

330

330

330

330

330

330

L2-02

Momentary Power Loss Ride-Thru Time

s

1.0 1.0 2.0 2.0 2.0 2.0 2.0 2.0

L2-05

Undervoltage Detection Level (Uv)

V

190

190

190

190

190

190

190

190

L2-21

AUv Detection Level

V

150

150

150

150

150

150

150

150

L8-02

Overheat Alarm Level

°C

110

125

115

125

130

135

135

130

L8-09

Output Ground Fault Detection Selection

1

1

1

1

1

1

1

1

L8-66

Power Supply Fault Detection Voltage Level

%

50

50

50

50

50

50

50

50

C7-47

Adjustment Reactor 1

mH

2.450

1.267 0.645 0.443 0.263 0.184 0.136 0.092

C7-51

Adjustment Reactor 2

mH

0.809

0.418 0.213 0.146 0.087 0.061 0.045 0.030

L8-35

Installation Method Selection

0

0

0

0

0

0

0

0

No.

Name

Unit

Default Settings

Model

4A0005 4A0010 4A0020 4A0030 4A0040 4A0060 4A0100 4A0130 4A0185 4A0270 4A0370 4A0630

o2-04 Model Selection Hex

97

9A

9D

9F

A1

A3

A5

A7

A9

AC

AE

B2

d8-01

DC Bus Voltage
Reference

V

660

660

660

660

660

660

660

660

660

660

660

660

L2-02

Momentary Power
Loss Ride-Thru
Time

s

0.5 1.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0

L2-05

Undervoltage
Detection Level
(Uv)

V

380

380

380

380

380

380

380

380

380

380

380

380

L2-21

AUv Detection
Level

V

300

300

300

300

300

300

300

300

300

300

300

300

L8-02

Overheat Alarm
Level

°C

110

115

115

115

115

130

140

145

140

130

130

130

L8-09

Output Ground
Fault Detection
Selection

1

1

1

1

1

1

1

1

1

1

1

1

L8-66

Power Supply
Fault Detection
Voltage Level

%

50

50

50

50

50

50

50

50

50

50

50

50

C7-47

Adjustment
Reactor 1

mH

9.189 4.594 2.450 1.710 1.267 0.855 0.507 0.350 0.245 0.179 0.131 0.064

C7-51

Adjustment
Reactor 2

mH

3.308 1.654 0.882 0.615 0.456 0.308 0.183 0.126 0.088 0.065 0.047 0.023

L8-35

Installation
Method Selection

0

0

0

0

0

0

0

0

0

0

0

0