6.4 Cooling Fans

148

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

4.

Remove the fan guard and replace the cooling fans.

Note: 1. Do not pinch the fan cable between parts when reassembling the fan unit.

2. Install the internal circulation fans so that they blow air upward. Install the cooling fan so that it blows air downward.

Figure 6.15

Figure 6.15 Fan Unit Disassembly

Cooling Fan Wiring: 2A0050, 4A0060, 4A0100

1.

Position the protective tube so the fan connector sits in the center of the protective tube.

2.

Place the fan connector covered by the tube.

Figure 6.16

Figure 6.16 Cooling Fan Wiring: 2A0050, 4A0060, 4A0100

3.

Make sure that the protective tube does not stick out beyond the fan guard.

A – Fan guard

C – Cooling fan (Air flow: Upward)

B – Cable cover

D – Circulation fan (Air flow: Downward)

A

A

B

C

C

D

B

A

C

Airflow

Airflow

Airflow

Airflow

2A0050, 4A0060, 4A0100

2A0130, 4A0130, 4A0185

2A0065, 2A0090

Protective tube

次回用

Connector for fan B1

Fan B1

Fan B2

2A0050

㧘4A0060

4A0100

Connector for fan B2

次回用