6.4 Cooling Fans
148
YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual
4.
Remove the fan guard and replace the cooling fans.
Note: 1. Do not pinch the fan cable between parts when reassembling the fan unit.
2. Install the internal circulation fans so that they blow air upward. Install the cooling fan so that it blows air downward.
Figure 6.15
Figure 6.15 Fan Unit Disassembly
Cooling Fan Wiring: 2A0050, 4A0060, 4A0100
1.
Position the protective tube so the fan connector sits in the center of the protective tube.
2.
Place the fan connector covered by the tube.
Figure 6.16
Figure 6.16 Cooling Fan Wiring: 2A0050, 4A0060, 4A0100
3.
Make sure that the protective tube does not stick out beyond the fan guard.
A – Fan guard
C – Cooling fan (Air flow: Upward)
B – Cable cover
D – Circulation fan (Air flow: Downward)
A
A
B
C
C
D
B
A
C
Airflow
Airflow
Airflow
Airflow
2A0050, 4A0060, 4A0100
2A0130, 4A0130, 4A0185
2A0065, 2A0090
Protective tube
次回用
Connector for fan B1
Fan B1
Fan B2
2A0050
㧘4A0060
4A0100
Connector for fan B2
次回用