Alarm (alm) led displays, Lo/re led and run led indications – Yaskawa D1000 Series Power Regenerative Converter User Manual

Page 88

Advertising
background image

4.2 Using the Digital Operator

88

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

ALARM (ALM) LED Displays

Table 4.2 ALARM (ALM) LED Status and Contents

LO/RE LED and RUN LED Indications

Table 4.3 LO/RE LED and RUN LED Indications

8

Function Key 2

(F1)

DATA

Pressing

scrolls to the next display.

Pressing

scrolls the cursor to the right.

RESET

Pressing

resets the existing converter fault or error.

<1> Displayed when in DC Bus Voltage Reference Mode.

<2> Displayed when in DC Bus Voltage Reference Mode and Monitor Mode.

State

Content

Display

Illuminated

When the converter detects a fault.

Flashing

• When an alarm occurs.
• When oPE is detected.

Off

Normal operation (no fault or alarm).

LED

Lit

Flashing

Off

<1> The indicator flashes in the following cases:

 When REMOTE operation is restored after inputting a Run command from an external terminal during LOCAL operation.

 A Run command was input from an external terminal in any mode other than Drive Mode.

 The STOP key on the digital operator was pressed during REMOTE operation.

When source of the Run command is
assigned to the digital operator
(LOCAL)

When a device other than the operator
is selected for Run command control
(REMOTE)

During run

Stopped for an operation interlock.

<1>

During stop

Examples

No.

Name

Display

Content

F1

F1

F1

RE

LO

RUN

TOEP_C710656_07C_2_0.book 88 ページ 2015年1月9日 金曜日 午後6時23分