5.3 Fault Detection

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

111

Tr

ou

blesh

oot

ing

5

Digital Operator

Display

Fault Name

Details

CPF06

EEPROM Memory

Data Error

Error in the data saved to EEPROM

Cause

Possible Solution

There is an error in EEPROM control circuit.

Turn off the power and check the connection between the control board and the converter.
If the problem continues, replace the control board or the entire converter. Contact Yaskawa or a
Yaskawa representative for instructions on replacing the control board.

The power supply was switched off while
parameters were being saved to the converter.

Reinitialize the converter (A1-03 = 2220, 3330).

Digital Operator

Display

Fault Name

Details

CPF07

Terminal Board

Connection Error

There is a faulty connection in the removable terminal block.

CPF08

Cause

Possible Solution

There is a faulty connection between the
terminal board and the control board.

• Turn off the power and reconnect the terminal board.
• If the problem continues, replace the control board or the entire converter. Contact Yaskawa or

a Yaskawa representative for instructions on replacing the control board.

Digital Operator

Display

Fault Name

Details

CPF23

Control Board

Connection Error

Connection error between the control board and the converter

Cause

Possible Solution

Hardware is damaged.

Turn off the power and check the connection between the control board and the converter.
If the problem continues, replace the control board or the entire converter. Contact Yaskawa or a
Yaskawa representative for instructions on replacing the control board.

Digital Operator

Display

Fault Name

Details

CPF24

Unit Capacity Detect

Fault

The converter capacity cannot be detected correctly (converter capacity is checked when the
converter is powered up).

Cause

Possible Solution

Hardware is damaged.

If the problem continues, replace the control board or the entire converter. Contact Yaskawa or a
Yaskawa representative for instructions on replacing the control board.

Digital Operator

Display

Fault Name

Details

E5

MECHATROLINK

Watchdog Timer Error

The watchdog timed out.

Cause

Possible Solution

Data has not been received from the PLC.

Execute DISCONNECT or ALM_CLR, then issue a CONNECT command or SYNC_SET
command and proceed to phase 3. Refer to the MECHATROLINK Option Technical Manual for
more details on troubleshooting.

Digital Operator

Display

Fault Name

Details

EF0

Option Card External

Fault

An external fault condition is present.

Cause

Possible Solution

An external fault was received from the PLC
and F6-03 is set to a value other than 3.

• Remove the cause of the external fault.
• Remove the external fault input from the PLC.

Problem with the PLC program

Check the PLC program and correct problems.

Digital Operator

Display

Fault Name

Details

EF1

External Fault

(input terminal S1)

External fault at multi-function input terminal S1.

EF2

External Fault

(input terminal S2)

External fault at multi-function input terminal S2.

TOEP_C710656_07C_2_0.book 111 ページ 2015年1月9日 金曜日 午後6時23分