Figure 3.13, Figure 3.14, Figure 3.15 – Yaskawa D1000 Series Power Regenerative Converter User Manual
Page 56: Figure 3.16, D1000, 4 terminal block configuration
Advertising

3.4 Terminal Block Configuration
56
YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual
Figure 3.13
Figure 3.13 Main Circuit Terminal Block Configuration (Models 2A0065, 2A0090)
Figure 3.14
Figure 3.14 Main Circuit Terminal Block Configuration (Models 2A0130, 4A0130 to 4A0185)
Figure 3.15
Figure 3.15 Main Circuit Terminal Block Configuration (Models 4A0270, 4A0370)
Figure 3.16
Figure 3.16 Main Circuit Terminal Block Configuration (Models 4A0630)
R/L1
S/L2
T/L3
r1/ℓ11 t1/ℓ31
1/ℓ21
r1/ℓ11 t1/ℓ31
1/ℓ21
D1000
R/L1
S/L2
T/L3
+
-
-
+
r1/ℓ11 t1/ℓ31
1/ℓ21
D1000
R/L1
S/L2
T/L3
+
-
+
-
r1/ℓ11 t1/ℓ31
1/ℓ21
D1000
-
-
+
+
R/L1
S/L2
T/L3
R1/L11
S1/L21
T1/L31
r1/ℓ11 t1/ℓ31
1/ℓ21
D1000
TOEP_C710656_07C_2_0.book 56 ページ 2015年1月9日 金曜日 午後6時23分