4 cooling fans, Number of cooling fans, Cooling fan component names – Yaskawa D1000 Series Power Regenerative Converter User Manual

Page 141: Number of cooling fans cooling fan component names, For details, Cooling fans

Advertising
background image

6.4 Cooling Fans

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

141

Per

iodic Ins

pec

tion

&

Maint

ena

nc

e

6

6.4 Cooling Fans

NOTICE: Follow cooling fan replacement instructions. The cooling fan cannot operate properly when installed incorrectly and could

seriously damage the converter. To ensure maximum useful product life, replace all cooling fans when performing maintenance.

Contact a Yaskawa representative or the nearest Yaskawa sales office to order replacement cooling fans as required.

For converters with multiple cooling fans, replace all the fans when performing maintenance to ensure maximum product
performance life.

WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious

personal injury. Before servicing the converter, disconnect all power to the equipment. The internal capacitor remains charged even

after the power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the converter before

touching any components.

CAUTION! Burn Hazard. Do not touch a hot converter heatsink. Failure to comply could result in minor or moderate injury. Shut off the

power to the converter when replacing the cooling fan. To prevent burns, wait at least 15 minutes and ensure the heatsink has cooled

down.

NOTICE: Follow cooling fan replacement instructions. Improper fan replacement could cause damage to equipment. Make sure the fan

is facing upwards when installing the replacement fan into the converter. Replace all fans when performing maintenance to help ensure

maximum useful product life.

Number of Cooling Fans

Cooling Fan Component Names

WARNING! Electrical Shock Hazard. Do not connect or disconnect wiring while the power is on. Failure to comply can result in serious

personal injury. Before servicing the converter, disconnect all power to the equipment. The internal capacitor remains charged even

after the power supply is turned off. After shutting off the power, wait for at least the amount of time specified on the converter before

touching any components.

CAUTION! Burn Hazard. Do not touch a hot converter heatsink. Failure to comply could result in minor or moderate injury. Shut off the

power to the converter when replacing the cooling fan. To prevent burns, wait at least 15 minutes and ensure the heatsink has cooled

down.

Three-Phase 200 V Class

Three-Phase 400 V Class

Model

Cooling

Fans

Circulation

Fans

Page

Model

Cooling

Fans

Circulation

Fans

Control Board

Cooling Fans

Page

2A0005

2

143

4A0005

2

143

2A0010

2

4A0010

2

2A0020

2

4A0020

2

2A0030

2

145

4A0030

2

145

2A0050

2

147

4A0040

2

2A0065

2

4A0060

2

147

2A0090

2

4A0100

2

2A0130

3

1

4A0130

3

4A0185

3

1

4A0270

3

2

2

151

4A0370

3

2

2

4A0630

6

4

4

155

TOEP_C710656_07C_2_0.book 141 ページ 2015年1月9日 金曜日 午後6時23分