3.8 Harmonic Filter Module Wiring
74
YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual
3.
Wire the R/L1, S/L2, and T/L3 terminals and then wire the X, Y, and Z terminals. Bundle the cables that are
connected to the X, Y, and Z terminals and secure them with cable ties.
Note: Wire the ground terminal first and then wire the main circuit terminals.
Figure 3.35
Figure 3.32 Wiring a Harmonic Filter Module
4.
Reverse the previous procedure and connect the faceplate and top cover.
EUJ71082 to EUJ71087 ,
EUJ71090 to EUJ71096
EUJ71080 , EUJ71081 ,
EUJ71088 , EUJ71089
D1000