A.4 derating data, Temperature derating, Altitude derating – Yaskawa D1000 Series Power Regenerative Converter User Manual

Page 178: Temperature derating altitude derating

Advertising
background image

178

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

A.4 Derating Data

A.4 Derating Data

The converter can be operated at above the rated temperature, altitude, and default carrier frequency by derating the
converter capacity.

Temperature Derating

To ensure the maximum performance life, the converter output current must be derated as shown in

Figure A.1

when the

converter is installed in areas with high ambient temperature or if converters are mounted side-by-side in a cabinet. In
order to ensure reliable converter overload protection, set parameters L8-35 according to the installation conditions.

Parameter Settings

If the ambient temperature is higher than the rating or if converters are installed side by side in the control panel, you must
set the L8-12 and L8-35 parameters according to the installation conditions. Derate the output current according to

Figure A.1

Setting 0: IP00/IP20/Open Type Enclosure

Converter operation between -10

°C and +50°C allows 100% continuous current without derating.

Setting 1: Side-by-Side Mounting

Converter operation between -10

°C and +30°C allows 100% continuous current without derating. Operation between

+30

°C and +50°C requires output current derating.

Setting 3: External Heatsink Installation

Converter operation between -10

°C and +40°C allows 100% continuous current without derating. Operation between

+40

°C and +50°C requires output current derating.

Figure A.1

Figure A.1 Ambient Temperature and Installation Method Derating

Altitude Derating

Standard ratings are valid for installation altitudes up to 1000 m. For installations from 1000 m to 3000 m, the converter
rated voltage and the rated output current must be derated for 1% per 100 m.

No.

Name

Description

Setting Value

Default Setting

L8-12

Ambient Temperature
Setting

Adjust the converter overload (oL2) protection level
when the converter is installed in an environment that
exceeds its ambient temperature rating.

-10 to +50

+40

°C

L8-35

Installation Method
Selection

0: IP00/IP20/Open Type Enclosure
1: Side-by-Side Mounting
3: External Heatsink Installation

0, 1, 3

Default setting is

determined by o2-04

(Drive Model

Selection).

100

85

70

55

0

L8-35=3: External Heatsink Installation

L8-35=0

:IP00/IP20/Open Type Enclosure

30

-10

40

50

L8-12
(Ambient temp: °C)

L8-35=1: Side-by-Side Mounting

TOEP_C710656_07C_2_0.book 178 ページ 2015年1月9日 金曜日 午後6時23分