Minor, Minor faults and alarms – Yaskawa D1000 Series Power Regenerative Converter User Manual

Page 107

Advertising
background image

5.2 Alarms, Faults, and Errors

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

107

Tr

ou

blesh

oot

ing

5

Minor Faults and Alarms

Refer to

Table 5.3

for an overview of possible alarm codes. Conditions such as overvoltages can trip faults and alarms. It

is important to distinguish between faults and alarms to determine the proper corrective actions. When the converter
detects an alarm, the ALM indicator LED blinks and the alarm code display flashes. Most alarms trigger a digital output
programmed for alarm output (H2- = 10). A fault (not an alarm) is present if the ALM LED lights without blinking.
Refer to

Faults on page 106

for information on fault codes.

Table 5.3 Minor Fault and Alarm Displays

<1> Displayed as CPF00 when occurring at converter power up. When one of the faults occurs after successfully starting the converter, the display

will show CPF01. Displayed as CPF20 when occurring at converter power up. When one of the faults occurs after successfully starting the

converter, the display will show CPF21.

Digital Operator Display

Name

Minor Fault Output

(H2- = 10)

Page

LED

LCD

AEr

Station Number Setting Error

YES

120

Aov

<1> Output when H2- = 2F.

Power Supply Overvoltage

YES

120

AUv

Power Supply Undervoltage

YES

120

bb

Converter Baseblock

No output

120

bUS

Option Card Communications Error

YES

121

CALL

Serial Communication Transmission Error

YES

121

CE

MEMOBUS/Modbus Communication Error

YES

121

CoF

Current Offset Fault

YES

122

CrST

Cannot Reset

YES

122

CyC

MECHATROLINK Communications Cycle Setting Error

YES

122

E5

MECHATROLINK Watchdog Timer Error

YES

122

EF0

Option Card External Fault

YES

122

to

EF1

to

EF8

External Fault (input terminal S1 to S8)

YES

123

Fan

Converter Internal Fan Fault

YES

123

Fdv

Power Supply Frequency Fault

YES

123

HCA

Current Alarm

YES

124

LT-1

Cooling Fan Maintenance Time

No output

<1>

124

LT-2

Capacitor Maintenance Time

No output

<1>

124

LT-3

Capacitor Maintenance Time

No output

<1>

124

oH

Heatsink Overheat

YES

124

oL2

Converter Overheat

YES

125

ov

Overvoltage

YES

125

PAUv

Power Supply Undervoltage Pre-alarm

YES

125

PF3

Input Phase Loss Detection

YES

126

SE

MEMOBUS/Modbus Test Mode Fault

YES

126

SrC

Phase Order Fault

YES

126

Uv

Undervoltage

YES

126

vrE

Resonance Detection

YES

127

TOEP_C710656_07C_2_0.book 107 ページ 2015年1月9日 金曜日 午後6時23分