Yaskawa D1000 Series Power Regenerative Converter User Manual

Page 224

Advertising
background image

C.9 MEMOBUS/Modbus Data Table

224

YASKAWA ELECTRIC TOEP C710656 07C YASKAWA Power Regenerative Converter - D1000 Instruction Manual

00C4H

Fault Contents 7
bit 0

Reserved

bit 1

External Fault 1, input terminal S1 (EF1)

bit 2

External Fault 2, input terminal S2 (EF2)

bit 3 - bit 4

Reserved

bit 5

Current Offset Fault (CoF)

bit 6 - bit F

Reserved

00C5H

Fault Contents 8
bit 0

Reserved

bit 1

Node Setup Fault (nSE)

bit 2 - bit F

Reserved

00C6H

Fault Contents 9
bit 0

Power Supply Module Undervoltage (Uv4)

bit 1 - bit 4

Reserved

bit 5

Power Supply Undervoltage (AUv)

bit 6

Power Supply Overvoltage (Aov)

bit 7

Power Supply Frequency Fault (Fdv)

bit 8

Power Phase Rotation Variation (SrC)

bit 9

Input Power Supply Fault (PF2)

bit A

Input Phase Loss 3 (PF3)

bit B - E

Reserved

bit F

AC Fuse Blowout (FUA)

00C7H

Reserved

00C8H

Alarm Contents 2
bit 0

Undervoltage (Uv)

bit 1

Overvoltage (ov)

bit 2

Heatsink Overheat (oH)

bit 3

Overheat 2 (oH2)

bit 4 - bit 6

Reserved

bit 7

Drive Baseblock (bb)

bit 8

External Fault 3, input terminal S3 (EF3)

bit 9

External Fault 4, input terminal S4 (EF4)

bit A

External Fault 5, input terminal S5 (EF5)

bit B

External Fault 6, input terminal S6 (EF6)

bit C

External Fault 7, input terminal S7 (EF7)

bit D

External Fault 8, input terminal S8 (EF8)

bit E

Cooling Fan Error (Fan)

bit F

Reserved

Register No.

Contents

TOEP_C710656_07C_2_0.book 224 ページ 2015年1月9日 金曜日 午後6時23分

Advertising