2 absolute data reception sequence, 1) outline of absolute data, 2) absolute data reception sequence – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 127: 48 and 65, Phase-c output specifications

Advertising
background image

4.7 Absolute Linear Scales

4-39

4

Op

er

at

io

n

4.7.2 Absolute Data Reception Sequence

The sequence in which the SERVOPACK receives outputs from the absolute linear scale and transmits them to

host controller is shown below.

(1) Outline of Absolute Data

The serial data, pulses, etc., of the absolute linear scale that are output from the SERVOPACK are output from
the PAO, PBO, and PCO signals as shown below.

Phase-C Output Specifications

The pulse width of phase C (origin pulse) changes depending on the encoder output resolution (Pn281),

becoming the same width as phase A.

The output timing is one of the following.

• Synchronized with the rising edge of phase A
• Synchronized with the falling edge of phase A
• Synchronized with the rising edge of phase B
• Synchronized with the falling edge of phase B

Note: When host controller receives the data of absolute linear scale, do not perform counter reset using the output of PCO

signal.

(2) Absolute Data Reception Sequence

1. Send the Turn Sensor ON (SENS_ON) command from the host controller.
2. After 100 ms, the system is set to serial data reception standby and the incremental pulse up/down counter

is cleared to zero.

3. Eight characters of serial data is received.
4. The system enters a normal incremental operation state about 400 ms after the last serial data is received.

Note: The output pulses are phase-B advanced if the servomotor is moving forward regardless of the setting in Pn000.0.

Signal Name

Status

Contents

PAO

At initialization

Serial data
Initial incremental pulses

Normal Operations

Incremental pulses

PBO

At initialization

Initial incremental pulses

Normal Operations

Incremental pulses

PCO

Always

Origin pulses

ENC

CN1

PAO

PBO

PCO

CN2

Serial

data

Serial data→

pulse conversion

Host

controller

SERVOPACK

Dividing

circuit

(Pn281)

48 and 65

PAO

PBO

SENS_ON
(Turn Sensor ON)

Incremental pulses

Incremental pulses

Undefined

Undefined

(Phase A) (Phase A)

(Phase B) (Phase B)

Serial data

400 ms max.

50 ms

1 to 3 ms

Approx. 15 ms

90 ms typ.

60 ms min.

Initial

incremental

pulses

Initial

incremental

pulses

65