3 mechatrolink-iii function specifications – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 28

Advertising
background image

1.3 SERVOPACK Ratings and Specifications

1-7

1

Outline

1.3.3 MECHATROLINK-III Function Specifications

The following table shows the specifications of MECHATROLINK-III.

Function

Specifications

MECHATROLINK-III

Communication

Communication Pro-

tocol

MECHATROLINK-III

Station Address

03H to EFH (Max. number of stations: 62)
Use the rotary switches S1 and S2 to set the station address.

Baud Rate

100 Mpbs

Transmission Cycle

125

μs, 250 μs, 500 μs, 750 μs, and 1.0 ms to 4.0 ms (incre-

ments of 0.5 ms)

Number of Transmis-

sion Bytes

16, 32, or 48 bytes per station
Use the DIP switch S3 to select the number of words.

Reference Method

Control Method

Position, speed, or force control with MECHATROLINK-

III communication

Reference Input

MECHATROLINK commands (sequence, motion, data set-
ting/reference, monitoring, or adjustment)

Profile

MECHATROLINK-III standard servo profile
MECHATROLINK-II-compatible profile

Advertising