9.1 List of Parameters

9-21

9

Ap

pend

ix

Pn512

2

Output Signal Inverse Setting 0000 to 0111

0000

After restart

Setup

3.3.2

Pn517

2

Reserved (Do not change.)

0000

Pn51E

2

Excessive Position Error
Warning Level

10 to 100

1%

100

Immediately

Setup

8.2.1

Pn520

4

Excessive Position Error
Alarm Level

1 to

1073741823

1

reference

unit

5242880

Immediately

Setup

5.1.4
8.1.1

Pn522

4

Positioning Completed Width

0 to

1073741824

1

reference

unit

7

Immediately

Setup

4.8.6

Pn524

4

NEAR Signal Width

1 to

1073741824

1

reference

unit

1073741824

Immediately

Setup

4.8.7

Pn526

4

Excessive Position Error
Alarm Level at Servo ON

1 to

1073741823

1

reference

unit

5242880

Immediately

Setup

5.1.4

Pn528

2

Excessive Position Error
Warning Level at Servo ON

10 to 100

1%

100

Immediately

Setup

Pn52B

2

Overload Warning Level

1 to 100

1%

20

Immediately

Setup

4.3.9

Pn52C

2

Derating of Base Current at
Detecting Overload of Motor

10 to 100

1%

100

After restart

Setup

Pn52D

2

Reserved (Do not change.)

50

Pn52F

2

Reserved (Do not change.)

0FFF

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

Output Signal Inversion for CN1-1 or -2 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Output Signal Inversion for CN1-23 or -24 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Output Signal Inversion for CN1-25 or -26 Terminal

0

Does not inverse outputs.

1

Inverses outputs.

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.