7 Monitor Displays (Un

)

7.3.1 Interpreting Input Signal Display Status

7-4

7.3 Monitoring Input Signals

The status of input signals can be checked with the input signal monitor (Un005). The procedure for the

method of interpreting the display and a display example are shown below.

7.3.1 Interpreting Input Signal Display Status

The input signal monitor (Un005) can be read in the following way. The upper level indicates OFF, and the

lower level indicates ON. All undefined digits are shown in the lower level (ON).

Note: Input signals use the following circuit configuration.

• OFF: Open
• ON: Short-circuited

Example

Display LED

Number

Input Terminal Name

Signal Name

(Factory Setting)

1

CN1-13

SIO

2

CN1-7

P-OT

3

CN1-8

N-OT

4

CN1-9

/DEC

5

CN1-10

/EXT1

6

CN1-11

/EXT2

7

CN1-12

/EXT3

8

Reserved

U n 0 0 5 =

8 7 6 5 4 3 2 1 digit

MECHA

OFF (open)