3 movement detection output signal (/tgon), 4 servo ready output signal (/s-rdy), 1) signal specifications – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 132: 2) related parameter

Advertising
background image

4 Operation

4.8.3 Movement Detection Output Signal (/TGON)

4-44

4.8.3 Movement Detection Output Signal (/TGON)

This output signal indicates that the servomotor is moving at the speed set for Pn581 or a higher speed.

(1) Signal Specifications

Note: Use parameter Pn50E.2 to allocate the /TGON signal for use. For details, refer to

3.3.2 Output Signal Alloca-

tions

.

(2) Related Parameter

Set the range in which the /TGON signal is output using the following parameter.

4.8.4 Servo Ready Output Signal (/S-RDY)

This signal is turned ON when the SERVOPACK is ready to accept the servo ON (SV_ON) command.

The /S-RDY signal is turned ON under the following conditions.

• The main circuit power supply is ON.
• No hard wire base block state
• No servo alarms
• The Turn Sensor ON (SENS_ON) command is received. (When an absolute linear scale is used.)
• Polarity detection has been completed. (When a servomotor without a hall sensor is used.)

If an absolute linear scale is used, the output of absolute data to the host controller must have been completed
when the SENS_ON command is received.

For details on the hard wire base block function, refer to 4.9.1 Hard Wire Base Block (HWBB) Function.

(1) Signal Specifications

Note 1. Use parameter Pn50E.3 to allocate the /S-RDY signal for use. For details, refer to 3.3.2 Output Signal Alloca-

tions.

2. For details on the hard wire base block function and the servo ready output signal, refer to 4.9.1 Hard Wire Base

Block (HWBB) Function.

Type

Signal

Name

Connector Pin

Number

Setting

Meaning

Output

/TGON

Must be allocated

ON (closed)

Servomotor is moving with the motor speed above
the setting in Pn581.

OFF (open)

Servomotor is moving with the motor speed below

the setting in Pn581.

Pn581

Zero Speed Level

 

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

1 to 10000

1 mm/s

20

Immediately

Setup

Speed

Position

Force

Type

Signal

Name

Connector Pin

Number

Setting

Meaning

Output

/S-RDY

Must be allocated

ON (closed)

The SERVOPACK is ready to accept the SV_ON
command.

OFF (open)

The SERVOPACK is not ready to accept the
SV_ON command.