8 Troubleshooting

8.2.2 Troubleshooting of Warnings

8-28

A.95A
Command

Warning 1
(Unsatisfying
Command)

Command sending con-

dition is not satisfied.

Refer to 8.3 Monitoring Communica-

tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the

warning.

Send a command after command

sending condition is satisfied.

A.95B
Command

Warning 2
(Non-supported
Command)

SERVOPACK received

unsupported command.

Refer to 8.3 Monitoring Communica-

tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the

warning.

Do not sent an unsupported command.

A.95D
Command

Warning 4
(Command Inter-
ference)

Command sending con-
dition for latch-related

commands is not satis-
fied.

Refer to 8.3 Monitoring Communica-

tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the
warning.

Send a command after command
sending condition is satisfied.

A.95E
Command

Warning 5
(Subcommand
Disable)

Subcommand sending
condition is not satis-
fied.

Refer to 8.3 Monitoring Communica-
tion Data on Occurrence of an Alarm
or Warning
to determine which
command was the cause of the
warning.

Send a command after command
sending condition is satisfied.

A.95F
Command Warn-

ing 6
(Undefined Com-
mand)

Undefined command
was sent.

Refer to 8.3 Monitoring Communica-
tion Data on Occurrence of an Alarm

or Warning to determine which
command was the cause of the
warning.

Do not use an undefined command.

A.960
MECHATROLINK
Communications

Warning

MECHATROLINK
wiring is incorrect.

Confirm the wiring.

Correct the MECHATROLINK wir-
ing.
Or, connect a terminal to the terminal

station.

MECHATROLINK
data reception error

occurred due to noise
interference.

Confirm the installation conditions.

Take measures against noise. Check
the MECHATROLINK communica-
tions cable and FG wiring and take
measures such as adding ferrite core
on the MECHATROLINK communi-
cations cable.

A SERVOPACK fault
occurred.

A fault occurred in the SERVOPACK.
Replace the SERVOPACK.

A.962
MECHATROLINK
Communications

Warning
(FCS Error)

MECHATROLINK
wiring is incorrect.

Confirm the wiring.

Correct the MECHATROLINK wir-
ing.
Or, connect a terminal to the terminal
station.

MECHATROLINK
data reception error
occurred due to noise
interference.

Confirm the installation conditions.

Take measures against noise. Check
the MECHATROLINK communica-
tions cable and FG wiring and take

measures such as adding ferrite core
on the MECHATROLINK communi-
cations cable.

A SERVOPACK fault
occurred.

A fault occurred in the SERVOPACK.
Replace the SERVOPACK.

(cont’d)

Warning Num-

ber: Warning

Name (Warning

Description)

Cause

Investigative Actions

Corrective Actions

Advertising