Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 282

Advertising
background image

8.1 Alarm Displays

8-21

8

Trou

blesh

ooting

A.E42:
MECHATROLINK

Station Address

Setting Error

The station address is out of the
allowable setting range.

Check the rotary switches, S1 and
S2, to see if the station address is
within the allowable range from 03

to EF.

Check the setting for the station
address of the host controller, and
reset the setting of the rotary
switches, S1 and S2 to change the

address to the proper value between
03 and EF.

Two or more stations on the com-
munications network have the
same address.

Check that two or more stations on
the communications network have
the same address.

Check the setting for the station
address of the host controller, and
reset the setting of the rotary

switches, S1 and S2 to change the
address to the proper value between
03 and EF.

A.E50:
MECHATROLINK

Synchronization Error

WDT data of host controller was
not updated correctly.

Check the WDT data updating for
the host controller.

Update the WDT data at the host
controller correctly.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still

occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E51:
MECHATROLINK

Synchronization

Failed

WDT data of host controller was
not updated correctly at the syn-
chronization communications
start, and synchronization com-
munications could not start.

Check the WDT data updating for
the host controller.

Update the WDT data at the host
controller correctly.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E60:
MECHATROLINK

Communications error
(Reception error)

MECHATROLINK wiring is
incorrect.

Check the MECHATROLINK wir-
ings.

Correct the MECHATROLINK wir-
ing.
Connect the terminator correctly.

MECHATROLINK data recep-
tion error occurred due to noise
interference.

Take measures against noise. Check
the MECHATROLINK communi-
cations cable and FG wiring and
take measures such as adding ferrite
core on the MECHATROLINK
communications cable.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still

occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E61:
MECHATROLINK

Transmission Cycle

Error
(Synchronization
interval error)

MECHATROLINK transmission
cycle fluctuated.

Check the MECHATROLINK
transmission cycle setting.

Remove the cause of transmission
cycle fluctuation at host controller.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

A.E62:
MECHATROLINK

Communications error
(FCS error)

MECHATROLINK wiring is
incorrect.

Check the MECHATROLINK wir-
ings.

Correct the MECHATROLINK wir-
ing.

MECHATROLINK data recep-
tion error occurred due to noise
interference.

Take measures against noise. Check
the MECHATROLINK communi-
cations cable and FG wiring and
take measures such as adding ferrite
core on the MECHATROLINK
communications cable.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions

Advertising