9 Appendix

9.1.2 Parameters

9-18

Pn50E

2

Output Signal Selection 1

0000 to 3333

0000

After restart

Setup

Pn50F

2

Output Signal Selection 2

0000 to 3333

0100

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

Positioning Completion Signal Mapping (/COIN)

Reference

Section

0

Disabled (the above signal is not used.)

4.8.6

1

Outputs the signal from CN1-1, 2 output terminal.

2

Outputs the signal from CN1-23, 24 output terminal.

3

Outputs the signal from CN1-25, 26 output terminal.

Speed Coincidence Detection Signal Mapping (/V-CMP)

Reference

Section

0 to 3

Same as /COIN Signal Mapping.

4.8.5

Servomotor Movement Detection Signal Mapping (/TGON)

Reference

Section

0 to 3

Same as /COIN Signal Mapping.

4.8.3

Servo Ready Signal Mapping (/S-RDY)

Reference

Section

0 to 3

Same as /COIN Signal Mapping.

4.8.4

4th 3rd 2nd 1st

digit digit digit digit

n.

Force Limit Detection Signal Mapping (/CLT)

Reference

Section

0

Disabled (the above signal is not used.)

4.6.3

1

Outputs the signal from CN1-1, 2 output terminal.

2

Outputs the signal from CN1-23, 24 output terminal.

3

Outputs the signal from CN1-25, 26 output terminal.

Speed Limit Detection Signal Mapping (/VLT)

Reference

Section

0 to 3

Same as /CLT Signal Mapping.

4.8.8

Brake Signal Mapping (/BK)

Reference

Section

0 to 3

Same as /CLT Signal Mapping.

4.3.4

Warning Signal Mapping (/WARN)

Reference

Section

0 to 3

Same as /CLT Signal Mapping.

4.8.2

4th 3rd 2nd 1st

digit digit digit digit

n.