6.11 Manual Offset-Signal Adjustment of the Motor Current Detection Signal (Fn00F)

6-19

6

Utili

ty Fu

ncti

ons (Fn

)

6.11 Manual Offset-Signal Adjustment of the Motor Current

Detection Signal (Fn00F)

Use this function only if the force ripple is still high after the automatic offset-signal adjustment of the motor
current detection signal (Fn00E).

Note: The adjusted value is not initialized by executing the Fn005 function (Initializing Parameter Settings).

(1) Preparation

The following condition must be met to manually adjust the offset of the motor current detection signal.

• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).

(2) Operating Procedure

Use the following procedure.

If this function is adjusted incorrectly and then executed, characteristics of the servomo-
tor performance could be affected.
Observe the following precautions when performing manual servo tuning.

• Run the servomotor at a speed of approximately 100 mm/s.
• Adjust the offset while monitoring the force reference with the analog monitor until the

ripple of force reference monitor's waveform is minimized.

• Adjust the phase-U and phase-V offset amounts alternately several times until these

offsets are well balanced.

Step

Display after Operation

Keys

Operation

1

Press the

Key to view the main menu for the

utility function.
Use the

or

Key to move through the list and

select Fn00F.

2

Press the

Key.

The display changes to the Fn00F execution display.

3

Send an SV_ON command from the host controller.

4

Adjust the phase-U offset.
Press the

or

Key to adjust the offset

amount.
Adjust the offset amount by 10 in the direction that
the force ripple is reduced.
Adjustment range: -512 to +511
(ZADJIU: Offset value of phase-U current)

5

Adjust the phase-V offset.
Press the

Key. The cursor moves to the phase-V

side.

6

Press the

or

Key to adjust the offset

amount.
Adjust the offset amount by 10 in the direction that
the force ripple is reduced.
Adjustment range: -512 to +511
(ZADJIV: Offset value of phase-V current)

B B

− F U N C T I O N −

F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r

B B
M a n u a l O f f s e t

− A D J

o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 0 9
Z A D J I V = - 0 0 0 0 6

R U N
M a n u a l O f f s e t

− A D J

o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 0 9
Z A D J I V = - 0 0 0 0 6

R U N
M a n u a l O f f s e t

− A D J

o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 0 6

R U N
M a n u a l O f f s e t

− A D J

o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 0 6

R U N
M a n u a l O f f s e t

− A D J

o f M o t o r C u r r e n t
Z A D J I U = - 0 0 0 1 9
Z A D J I V = - 0 0 0 1 6

Advertising