Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 26

Advertising
background image

1.3 SERVOPACK Ratings and Specifications

1-5

1

Outline

I/O

Signals

Encoder Output Pulse

Phase A, B, C: line driver
Encoder output pulse: any setting ratio (Refer to 4.4.5.)

Sequence

Input

Input

Signals

which can

be allocated

Number of

Channels

7 ch

Functions

• Homing deceleration switch (/DEC)
• External latch (/EXT 1 to 3)
• Forward run prohibited (P-OT), reverse run prohibited

(N-OT)

• Forward external force limit (/P-CL), reverse external

force limit (/N-CL)

Signal allocations can be performed, and positive and
negative logic can be changed.

Sequence

Output

Fixed Output Servo alarm (ALM) output

Output

Signals

which can

be allocated

Number of

Channels

3 ch

Functions

• Positioning completion (/COIN)
• Speed coincidence detection (/V-CMP)
• Movement detection (/TGON)
• Servo ready (/S-RDY)
• Force limit detection (/CLT)
• Speed limit detection (/VLT)
• Brake (/BK)
• Warning (/WARN)
• Near (/NEAR)

Signal allocations can be performed, and positive and
negative logic can be changed.

Communi-

cations

Function

RS422A

Commu-

nications

(CN3)

Interface

Digital operator (JUSP-OP05A-1-E), personal computer (can be connected
with SigmaWin+)

1:N

Communica-

tions

N = Up to 15 stations possible at RS422A

Axis

Address

Setting

Set by parameter

USB

Commu-

nications

(CN7)

Interface

Personal computer (can be connected with SigmaWin+)

Communica-

tions

Standard

Complies with standard USB1.1. (12 Mbps)

LED Display

Panel display (seven-segment), CHARGE, L1, L2, and CN indicators

MECHATROLINK-III

Communications Setting Switches

Rotary Switch
(S1, S2)

Position: 16 positions

× 2 (Refer to 4.1.1)

DIP Switch (S3)

Number of pins: Four pins (Refer to 4.1.1)

Analog Monitor (CN5)

Number of points: 2
Output voltage:

±

10VDC (linearity effective range

±

8 V)

Resolution: 16 bits
Accuracy:

±

20 mV (Typ)

Max. output current:

±

10 mA

Settling time (

±

1%): 1.2 ms (Typ)

Dynamic Brake (DB)

Activated when a servo alarm or overtravelling occurs or when the power
supply for the main circuit or servomotor is OFF.

Regenerative Processing

Included

*4

Overtravel Prevention (OT)

Dynamic brake stop, deceleration to a stop, or free run to a stop at P-OT or
N-OT

Protective Function

Overcurrent, overvoltage, insufficient voltage, overload, regeneration error,
and so on.

Utility Function

Gain adjustment, alarm history, JOG operation, origin search, and so on.

(cont’d)

Advertising