5.1 Type of Adjustments and Basic Adjustment Procedure

5-5

5

Adjustments

5.1.3 Monitoring Operation during Adjustment

Check the operating status of the machine and signal waveform when adjusting the servo gain. Connect a mea-

suring instrument, such as a memory recorder, to connector CN5 analog monitor connector on the SERVO-

PACK to monitor analog signal waveform.

The settings and parameters for monitoring analog signals are described in the following sections.

(1) Connector CN5 for Analog Monitor

To monitor analog signals, connect a measuring instrument with cable (JZSP-CA01-E) to the connector CN5.

(2) Monitor Signal

The shaded parts in the following diagram indicate analog output signals that can be monitored.

Line Color

Signal Name

Factory Setting

White

Analog monitor 1

Force reference: 1 V/100% rated force

Red

Analog monitor 2

Motor speed: 1 V/1000 mm/s

Black (2 lines)

GND

Analog monitor GND: 0 V

CN5

JZSP-CA01-E

White

Red

Black

Black

Probe GND

Measuring
Probe

Probe GND

Measuring
Probe

White

Red

Black

Black

CN5

Measuring
Instrument*

Connection Example

∗ Measuring instrument is not included.

M-III

ENC

CN2

(U/V/W)

+

+

+

+

+

Force
reference

Speed
reference

Position
reference

+

1

SERVOPACK

Speed feedforward

Position reference speed

Position

amplifier error

Motor speed

Speed reference

Active gain

Force

reference

Speed

conversion

Electronic

gear

Speed

loop

Current

loop

Electronic

gear

Position loop

Force feedforward

Error

counter

Error

counter

Load

M

Kp

Position error

Positioning
completed

Completion of position
reference

Speed

conversion

48 and 65