9 Appendix

9.1.2 Parameters

9-24

Pn800

2

Communications Control

1040

Immediately

Setup

∗9. This parameter is enabled only for MECHATROLINK-III standard servo profile.

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

MECHATROLINK-III Communications Check Mask (for debug)

0

No mask

1

Ignores MECHATROLINK communications error (A.E6 ).

2

Ignores WDT error (A.E5 ).

3

Ignores both MECHATROLINK communications error (A.E6 ) and WDT error (A.E5 ).

Warning Check Mask

0

No mask

1

Ignores data setting warning (A.94 ).

2

Ignores command warning (A.95 ).

3

Ignores both data setting warning (A.94 ) and command warning (A.95 ).

4

Ignores communications warning (A.96 ).

5

Ignores both data setting warning (A.94 ) and communications warning (A.96 ).

6

Ignores both command warning (A.95 ) and communications warning (A.96 ).

7

Ignores data setting warning (A.94 ), command warning (A.95 ) and communications warning
(A.96 ).

8

Ignores command warning 7 (A.97A) and data clamp (A.97B).

9

Ignores data setting warning (A.94 ), command warning 7 (A.97A) and data clamp (A.97B).

A

Ignores command warning (A.95 ) and command warning 7 (A.97A) and data clamp (A.97B).

B

Ignores data setting warning (A.94 ), command warning (A.95 ), command warning 7 (A.97A)
and data clamp (A.97B).

C

Ignores communications warning (A.96 ), command warning 7 (A.97A) and data clamp (A.97B).

D

Ignores data setting warning (A.94 ), communications warning (A.96 ), command warning 7
(A.97A) and data clamp (A.97B).

E

Ignores command warning (A.95 ), communications warning (A.96 ), command warning 7
(A.97A) and data clamp (A.97B).

F

Ignores data setting warning (A.94 ), command warning (A.95 ), communications warning
(A.96 ), command warning 7 (A.97A) and data clamp (A.97B).

Reserved (Do not change.)

Automatic warning-clear (for debug)

*9

0

No warning-clear (for debug)

1

Automatic warning-clear (for MECHATROLINK-III specifications)

4th 3rd 2nd 1st

digit digit digit digit

n.