Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 308

Advertising
background image

9 Appendix

9.1.2 Parameters

9-10

Pn139

2

Automatic Gain Changeover
Related Switch 1

0000 to 0052

0000

Immediately

Tuning

5.8.1

Pn13D

2

Current Gain Level

100 to 2000

1%

2000

Immediately

Tuning

5.8.4

Pn140

2

Model Following Control
Related Switch

0000 to 1121

0100

Immediately

Tuning

Pn141

2

Model Following Control
Gain

10 to 20000

0.1/s

500

Immediately

Tuning

Pn142

2

Model Following Control
Gain Compensation

500 to 2000

0.1%

1000

Immediately

Tuning

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classi-

fication

Profile

Reference

Section

Gain Switching Selection Switch

0

Manual gain switching
Changes gain manually using G-SEL of the servo command output signals (SVCMD_IO).

1

Reserved (Do not change.)

2

Automatic gain switching pattern 1
Changes automatically 1st gain to 2nd gain when the switching condition A is satisfied.
Changes automatically 2nd gain to 1st gain when the switching condition A is not satisfied.

Gain Switching Condition A

0

Positioning completion signal (/COIN) ON

1

Positioning completion signal (/COIN) OFF

2

Positioning near signal (/NEAR) ON

3

Positioning near signal (/NEAR) OFF

4

Position reference filter output = 0 and position reference input OFF

5

Position reference input ON

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Model Following Control Selection

0

Does not use model following control.

1

Uses model following control.

Vibration Suppression Selection

0

Does not perform vibration suppression.

1

Performs vibration suppression over the specified frequency.

2

Performs vibration suppression over two different kinds of frequencies.

Vibration Suppression Adjustment Selection

Reference

Section

0

Does not adjust vibration suppression automatically using utility function.

5.3.1, 5.4.1,

5.5.1, 5.7.1

1

Adjusts vibration suppression automatically using utility function.

Selection of Speed Feedforward (VFF) / Force Feedforward (TFF)

Reference

Section

0

Does not use model following control and speed/force feedforward together.

5.3.1, 5.4.1

1

Uses model following control and speed/force feedforward together.

4th 3rd 2nd 1st

digit digit digit digit

n.

Advertising