3 Wiring and Connection

3-26

3.5 Wiring MECHATROLINK-III Communications

The following diagram shows an example of connections between a host controller and a

SERVOPACK.

Connect the MECHATROLINK-III communications cables to the CN6A and CN6B on the SERVOPACK as

shown below.

Note: The length of the cable between stations (L1, L2 ... Ln) must be 75 m maximum.

For removing the MECHATROLINK-III communications cable connectors from the SERVOPACK, refer to the following
procedure.
Slide the lock injector of the connector to the SERVOPACK side to unlock and remove the MECHATROLINK-III com-
munications cable connectors.

Note: The MECHATROLINK-III communications cable connector may be damaged if it is removed without being

unlocking.