4) transferring alarm contents, Linear, M-iii – Yaskawa Sigma-5 User Manual: Design and Maintenance - Linear Motors MECHATROLINK-III Communications Reference User Manual

Page 129

Advertising
background image

4.7 Absolute Linear Scales

4-41

4

Op

er

at

io

n

(3) Serial Data Specifications and Initial Incremental Pulses

Serial Data Specifications

The serial data is output from PAO signal.

Initial Incremental Pulses

The initial incremental pulses are output after division inside the SERVOPACK in the same way as for normal

incremental pulses. Refer to 4.4.4 Encoder Output Pulses for details.

(4) Transferring Alarm Contents

If an absolute linear scale is used, the contents of alarms detected by the SERVOPACK are transmitted in

serial data to the host controller from the PAO output when the Turn Sensor OFF command (SENS_OFF) is

received.

Note: The SENS_OFF command cannot be received while the servomotor power is ON.

Output example of alarm contents are as shown below.

Data Transfer

Method

Start-stop Synchronization (ASYNC)

Baud rate

9600 bps

Start bits

1 bit

Stop bits

1 bit

Parity

Even

Character code

ASCII 7-bit code

Data format

8 characters, as shown below.

Note 1. The range for absolute data is "P+00000" (CR) or "P-00000" (CR).

2. The serial data range is "-32768" to "+32767". When this range is exceeded, the data

changes from "+32767" to "-32678" or from "-32678" to "+32767".

3. In the case of reverse direction mode (Pn000.0 = 1), the sign reverses.

Data

Start bit

Even parity

Movement data
in five digits

"+" or " - "

"0" to "9"

"CR"

"P"

Stop bit

0 0 0 0 0 1 0 1 0 1

Linear

OFF

Error detection

ON

Incremental pulse

Serial Data

Enlarged view

Turn Sensor
OFF
(SENS_OFF)

Panel Display

PAO Output

Serial Data Format

Upper 2 digits

A

L

M

5

1

.

CR

" "

" "

" "

" "

" "

" " "

"

or

Overspeed

M-III